Case: T17DV02739
Case Details
Entered Date:
06/26/2017
Applicant:
ANN M BOYCE
Description:
EXTERIOR BUILDING CODE VIOLATIONS 15
Case Violations
Case Number: T17DV02739
Case Status: COMPLIAN
Case Description: DILAPIDATED STRUCTURE
Total Violations: 2
Violation Date | Code Statue |
---|---|
06/27/2017 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
06/28/2017 | NOTICE OF VIOLATION ISSUED |
Outstanding Inspections
Case Number: T17DV02739
Case Status: COMPLIAN
Case Description: DILAPIDATED STRUCTURE
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/13/2017 | NPO(DL)-DILAPIDATED STRUCTURE | BIGMAN | Follow-up inspection | |
09/13/2017 | NPO - WORK WITHOUT PERMIT | BIGMAN | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T17DV02739
Case Description: DILAPIDATED STRUCTURE
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2017 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | ONSITE INSPECTION OF BLDG. 15 EXTERIOR INSPECTION OF BUILDING 15, THIS BUILDING IS A 2 STORY BUILDING WITH 12 UNITS. THE BUILDING IS A CMU TYPE BUILDING. . THE FRONT OF THE BUILDING HAS AN OPEN PORCH WITH A STEEL FRAMED STAIRCASE WITH CONCRETE STEPS. THE REAR OF THE BUILDING HAS A WOOD FRAMED REAR CANTILEVER BALCONY WITH DECKING BOARDS AND A METAL RAILING. THIS WAS A VISUAL INSPECTION FROM THE GROUND FLOOR. BELOW ARE THE CODE VIOLATIONS FRONT OF THE BUILDING DECKING BOARDS HAVE DETERIORATED AND ARE DAMAGED DUE TO WOOD ROT. METAL RAILINGS HAS MISSING HARDWARE, PORTIONS OF THE RAILING HAVE EXCESSIVE RUST. THE ARE AREAS OF THE RAILING WHICH HAVE RUST HOLES IN THE POSTS AND BALUSTERS, SOME OF THE RAILINGS ARE NOT ATTACHED OR LOOSE IN SOME AREAS. THE FRAMED METAL STAIRCASE HAS SEVERE RUST IN AREAS WHICH SUPPORTS THE CONCRETE STEPS. THERE IS DAMAGE TO MULTIPLE BEAM POCKETS, EITHER BROKEN OR MISSING BLOCK. BEAMS DAMAGE PRESENT AT THE POINT OF CONNECTION TO THE POST DUE TO WOOD ROT MULTIPLE BEAMS HAVE MISSING HARDWARE. REAR OF THE BUILDING THE BALCONIES HAVE HEAVY DETERIORATION AND WOOD ROT DAMAGE TO THE CANTILEVERED BEAMS, DECKING BOARDS AND FLOOR JOISTS. MOST OF THE DECKING BOARDS HAVE UPLIFTED WITH MISSING FASTENERS. THERE ARE MULTIPLE FLOOR JOISTS WITH SEVERE WOOD ROT DAMAGE THE BALCONY METAL RAILINGS HAS MISSING HARDWARE. |
09/13/2017 | INSP - FOLLOW UP CODE ENFORCE | BIGMAN | Approved | OWNER OBTAINED A PERMIT FOR REPAIRS TO BALCONIES AND DECKING. T17CM05710. |
Completed Activity Special Conditions
Case Description - DILAPIDATED STRUCTURE
Case Number - T17DV02739
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date | Name |
06/27/2017 | CONTACTED IN PERSON |
06/28/2017 | CONTACTED BY MAILING |