Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

05/30/2017

Applicant:

1050 EAST MOSSMAN LLC

Description:

NO AC, ELECTRICAL OUTLETS ARE SPARKING.

Outstanding Inspections

Case Number: T17DV02197
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 12
End Date Description Inspector Results Comments
08/17/2017 NPO(EL)-MAIN/PANEL/SUB/DISCONT VIDAL Item closed
08/17/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX VIDAL Item closed
08/17/2017 NPO(PL)-PLUMBING SYSTEM & FX VIDAL Item closed
08/17/2017 NPO(PL)-GAS SUPPLY/CONNECT VIDAL Item closed
08/17/2017 NPO(PL)-WATER HEATERS VIDAL Item closed
08/17/2017 NPO(HC)-COOLING VIDAL Item closed
08/17/2017 NPO - EGRESS VIDAL Item closed
08/17/2017 NPO - SMOKE ALARMS VIDAL Item closed
08/17/2017 NPO - OTHER VIDAL Item closed
08/17/2017 NPO - EXT. BUILDING MAINTENANC VIDAL Item closed
08/17/2017 NPO - WORK WITHOUT PERMIT VIDAL Item closed
08/17/2017 NPO - INT. BUILDING MAINTENANC VIDAL Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV02197
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
End Date Description Inspector Results Comments
05/31/2017 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Met with the tenant and the tenant is renting with option to buy. I did ask if she owns the mobile home and stated that she is only renting and has contract with agreements to buy the mobile home. The tenant has been trying to get the repairs done and the manager wants the tenant to pay due to the option to buy. Did call Rick Saldate the administrator due to the agreements that exist. The tenant does not have the title and making payments for rent only. Rick agrees that the owner of the mobile home park is still responsible for the mobile home and will be giving the paperwork to the manager. Did call the manager and discuss the situation on site and she was coming to the property to do lock outs on the electric, gas and the water at the meters. Wires are mixed with copper and aluminum in the outlets and the switches for lights and the cooler, the dead front was missing on the panel in the closet and all had signs of arcing inside the boxes. Smelled gas in the kitchen area by the stove, has a window AC added to a opening in the hallway and not mounted properly, windows are screwed shut, steps are lacking to the side door and the door is screwed shut and blocked on the exrerior, the cooler was not working and the switch fell to the ground when trying to check it, lacking smoke detectors and some windows broken at the glass, switches and outlets are loose or not mounted properly or broken, the water is leaking at the connection to the mobile home near the hose bibb at the rear of the mobile home, the front porch is loose and weathered at the ends of the sheathing due to lacking the roof covering, has extension cords through out due to oulets are not working and the mobile has other issues and will check with all the other repairs have been completed. Will need to check for min. housing condition when the tenant want to move back in if she wants to. The manager signed the paperwork and did the posting on the front window of Do Not Enter. The electrical work needs to be done by a electrical contractor and a permit is being requested for the work to be done. Will check in 10 days. RV.
05/31/2017 INSP - INITIAL CODE ENFORCMENT HOLLANDER Approved Was called out for an electrical assist. Found alluminum conductors and copper conductors connected together at devices. Occupant is reporting arcing and fires at the receptacles. We found non-connected wires in boxes. There is an extention cord ran under the carpet for a window unit A/C. The dead front is missing for the panel in the closet exposing combustables and people to live electric. There are misc extention cords through out the unit. Main pedistall has an improper grounding electrode system. The pedistall has an open space in the middle cover exposing live busses.
08/17/2017 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved The mobile home is vacant and secured and the posting still on the front window. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T17DV02197
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
05/31/2017 NOTICE OF VIOLATION ISSUED
05/31/2017 VIOLATION CLOSED
08/17/2017 STRUCTURE SECURED BY ???