Case Details

Status:

NOVERIFY

Type:

RES: MINIMUM HOUSING

Entered Date:

04/19/2017

Applicant:

WOJCIECH & KATARZYNA CAL CP/RS

Description:

Faulty or improper wiring; Improper/unsafe weather proofing/ventilation; unsafe roof support over front door; plumbing both bathtubs. issues with the windows. I spoke with Paula on Wed. 4/19/17 She infromed me that she works tue, wed, and thurdays, she is usually off on Mondays and Fridays. She lives in a gated community that has a gate code to get in. When you call her she will have to give you this code. She also plans on moving out in 30 days, just an FYI.

Case Violations

Case Number: T17DV01632
Case Status: NOVERIFY
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
04/27/2017 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element.
04/27/2017 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
04/27/2017 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
04/27/2017 T.C. Ch. 16, Sec. 16-11(b) (3) VENTILATION. b. Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room.
04/27/2017 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T17DV01632
Case Status: NOVERIFY
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
05/22/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX VINDIOLA Item closed
05/22/2017 NPO(PL)-PLUMBING SYSTEM & FX VINDIOLA Item closed
05/22/2017 NPO(HC)-HEATING & VENTILATION VINDIOLA Item closed

Completed Inspections

Case Status: NOVERIFY
Case Number: T17DV01632
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/24/2017 INSP - INITIAL CODE ENFORCMENT VINDIOLA Approved Arrived on site and met with tenant who showed me into the property found roof area in back of the carport and also by front door with weather damage to the wood itself. Front window by front door also has gaps and is not shutting properly is not weather tight. Outdoor lighting to storage room and front door are not operational. Both bathroom tub Stoppers are not operational period exhaust fan and first bathroom not operational.
05/22/2017 INSP - FOLLOW UP CODE ENFORCE VINDIOLA Approved On site today was able to get into front gates from old tenant however she is not occuping property anymore, living at her new apt. Rang bell at garage area but no answer and unable to follow up on any movement. We lost acess to property by tenant moving, will move to close out this case

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T17DV01632
Case Status: NOVERIFY
Total Completed Case Activity Conditions: 4
Date Name
04/24/2017 CONTACTED BY PHONE
05/01/2017 CONTACTED BY MAILING
05/01/2017 NOTICE OF VIOLATION ISSUED
06/05/2017 VIOLATION CLOSED