Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

CAR THROUGH RESIDENTIAL BUILDI

Entered Date:

02/11/2017

Applicant:

WILCH MARGARET & ROZEK MARILYN M

Description:

CAR INTO BUILDING

Outstanding Inspections

Case Number: T17DV00625
Case Status: COMPLIAN
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
07/21/2017 EMERGENCY CALL OUT VALDEZ Item closed
07/21/2017 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item closed
07/21/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item closed
07/21/2017 NPO(DL)-DILAPIDATED STRUCTURE VALDEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV00625
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/11/2017 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved A VEHICLE HIT THE NORTH EAST CORNER OF THE HOME, THE HOME IS SLUMP BLOCK TYPE CONSTRUCTION. THE IMPACT DID DESTROY A 20 FOOT SECTION OF THE FRONT SECTION OF THE EXTERIOR WALL, A 20 FOOT SECTION OF THE NORTH EXTERIOR WALL BEARING WAS ALSO DESTROYED. THE NE CORNER OF THE HOME HAD A MASONRY CHIMNEY WHICH WAS ALSO DESTROYED. THERE WERE 7 RAFTERS WERE DAMAGED, TWO WINDOWS WERE DAMAGED, ONE IS A 3 X 5 ENCASEMENT TYPE WINDOW THE OTHER IS A 3 X 5 PICTURE WINDOW. THERE IS WIRING AND FLEX CONDUIT WHICH WAS PULLED AND DAMAGED IN THIS AREA, THE MAIN DISCONNECT BREAKERS ARE OFF. ATTACHED TO THE NORTHSIDE OF THE HOME IS A 20 X20 WOOD FRAMED PATIO WITH 6 RAFTERS UNABLE TO SUPPORT ITS OWN WEIGHT DUE TO THE DAMAGED TO BEARING NORTH WALL. THE FRONT EXTERIOR WALL OF THE HOME HAS MULTIPLE CRACKING FROM THE FOUNDATION TO THE RIDGE AREA AND UNDER THE TILE ROOF COVERING.. THE ROOF COVERING TILES ALSO DAMAGE IN THIS AREA. POWER WAS TURNED BACK ON TO THE REAR GUEST HOUSE. THE MAIN DISCONNECT HAS NO MAIN BREAKER AND 7 CIRCUIT BREAKERS. PHOTOS IN SIRE
07/21/2017 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved T17CM04823 IN GOOD STANDING CLOSE CASE PER SUPERVISION.

Completed Activity Special Conditions

Case Description - CAR THROUGH RESIDENTIAL BUILDI
Case Number - T17DV00625
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
02/14/2017 CONTACTED BY PHONE
02/11/2017 CONTACTED IN PERSON
02/14/2017 CONTACTED BY EMAIL
02/11/2017 NOTICE AND ORDER ISSUED
07/21/2017 VIOLATION CLOSED
02/11/2017 STRUCTURE SECURED BY ???
02/11/2017 CALLBACK

Documents

File Name Document Type  
20170211_031636.JPG DOCUMENTS VIEW
20170211_031705.JPG DOCUMENTS VIEW
20170211_032102.JPG DOCUMENTS VIEW
20170211_032122.JPG DOCUMENTS VIEW
20170211_032628.JPG DOCUMENTS VIEW
20170211_033130.JPG DOCUMENTS VIEW
20170211_033145.JPG DOCUMENTS VIEW
20170211_033158.JPG DOCUMENTS VIEW
20170211_033905.JPG DOCUMENTS VIEW
20170211_033911.JPG DOCUMENTS VIEW
20170211_033925.JPG DOCUMENTS VIEW
20170211_034010.JPG DOCUMENTS VIEW
20170211_034030.JPG DOCUMENTS VIEW
20170211_034904.JPG DOCUMENTS VIEW
20170211_065609.JPG DOCUMENTS VIEW
20170211_065707.JPG DOCUMENTS VIEW
20170211_080816.JPG DOCUMENTS VIEW
20170211_080849.JPG DOCUMENTS VIEW
20170211_080906.JPG DOCUMENTS VIEW
1929 N FORGEUS AV.PDF DOCUMENTS VIEW
1929 N FORGEUS DAMAGE REPORT.PDF DOCUMENTS VIEW