Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING

Entered Date:

01/07/2017

Applicant:

NEW MANAGER JUAN CASTANEDA

Description:

COMMERCIAL FIRE

Outstanding Inspections

Case Number: T17DV00060
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
07/12/2017 EMERGENCY CALL OUT VALDEZ Item closed
07/12/2017 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item closed
07/12/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item closed
07/12/2017 NPO(PL)-PLUMBING SYSTEM & FX VALDEZ Item closed
07/12/2017 NPO(DL)-DILAPIDATED STRUCTURE VALDEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV00060
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/07/2017 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: HOOD FIRE AT KFC, TFD STATED THAT THERE WAS FIRE IN AND ABOVE THE HOOD AROUND THE EXHAUST DUCT. THE HOOD IS ESTIMATE 16 FEET LONG WITH ONE 16" X16" EXHAUST DUCT, WHILE THE DROPPED DOWN CEILING TILES WERE REMOVED BY TFD, I SAW A CUT OUT IN THE CEILING FOR ANOTHER EXHAUST DUCT WHICH WAS COVERED UP. THE SIDE OF THE HOOD WHICH DOESN'T HAVE AN EXHAUST DUCT HAS (2) HOT HOLDING UNITS (OVEN WARMERS) UNDERNEATH. IM CONCERNED ABOUT ONLY ONE DUCT FOR THE ENTIRE HOOD SYSTEM. THE FRYERS WERE LEFT ON. THERE IS MC CABLE ABOVE THE HOOD AND AN OUTLET WITH A DUPLEX RECEPTACLE SATURATED WITH OIL BEHIND THE FRYERS. THE ANSUL SYSTEM DID NOT DEPLOY. THERE IS NO STRUCTURAL DAMAGE TO THE BUILDING. SWG DID SHUT THE GAS OFF. TEP DID LOCK OUT THE POWER. THERE IS DAMAGE TO THE CEILING TILES. THE 4 INTERIOR PANELS HAVE CODE VIOLATIONS, CIRCUIT BREAKERS WHICH ARE UNREADABL, DAMAGED AND NO LABELING ON THE PANELS. ONE CIRCUIT BREAKER HAS A HOMEMADE HANDLE TIE. THE FRONT DOOR TO THE BUILDING WERE FORCED OPEN, THE MANAGER DID SECURED THE BUILDING, THE BUILDING WAS CONDEMNED, PERMITS REQUIRED FOR REPAIRS TO THE HOOD SYSTEM, FIRE SYSTEM, ELECTRICAL AND GAS, SCHEDULE A 30 DAYS INSPECTION FOR THE AREA INSPECTOR
07/12/2017 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved CURRENT PERMIT IS ON HOLD DUE TO EXCESSIVE WORK REQUIRED PER BUILDING OFFICIAL . BUILDING IS VACANT AND SECURED. CLOSE CASE

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T17DV00060
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
01/27/2017 CONTACTED BY PHONE
01/07/2017 CONTACTED IN PERSON
01/27/2017 CONTACTED BY EMAIL
01/07/2017 NOTICE AND ORDER ISSUED
07/12/2017 VIOLATION CLOSED
01/07/2017 CALLBACK

Documents

File Name Document Type  
20170107_010743.JPG DOCUMENTS VIEW
20170107_010910.JPG DOCUMENTS VIEW
20170107_010918.JPG DOCUMENTS VIEW
20170107_010930.JPG DOCUMENTS VIEW
20170107_010940.JPG DOCUMENTS VIEW
20170107_011020.JPG DOCUMENTS VIEW
20170107_011038.JPG DOCUMENTS VIEW
20170107_011046.JPG DOCUMENTS VIEW
20170107_011051.JPG DOCUMENTS VIEW
20170107_011127.JPG DOCUMENTS VIEW
20170107_011142.JPG DOCUMENTS VIEW
20170107_011326.JPG DOCUMENTS VIEW
20170107_011331.JPG DOCUMENTS VIEW
20170107_011337.JPG DOCUMENTS VIEW
20170107_011512.JPG DOCUMENTS VIEW
20170107_011542.JPG DOCUMENTS VIEW
20170107_011558.JPG DOCUMENTS VIEW
20170107_011645.JPG DOCUMENTS VIEW
20170107_012003.JPG DOCUMENTS VIEW
20170107_012127.JPG DOCUMENTS VIEW
20170107_012148.JPG DOCUMENTS VIEW
20170107_012202.JPG DOCUMENTS VIEW
20170107_012255.JPG DOCUMENTS VIEW
20170107_012304.JPG DOCUMENTS VIEW
20170107_012328.JPG DOCUMENTS VIEW
20170107_012442.JPG DOCUMENTS VIEW
20170107_013537.JPG DOCUMENTS VIEW
20170107_013549.JPG DOCUMENTS VIEW
20170107_013706.JPG DOCUMENTS VIEW
20170107_013829.JPG DOCUMENTS VIEW
20170107_025713.JPG DOCUMENTS VIEW
1065 S CRAYCROFT RD.PDF DOCUMENTS VIEW
20170428_091554.JPG DOCUMENTS VIEW
20170428_091600.JPG DOCUMENTS VIEW
20170428_091618.JPG DOCUMENTS VIEW
20170428_091747.JPG DOCUMENTS VIEW
20170428_091802.JPG DOCUMENTS VIEW
20170428_091813.JPG DOCUMENTS VIEW
20170428_092056.JPG DOCUMENTS VIEW
20170428_092101.JPG DOCUMENTS VIEW
20170428_092146.JPG DOCUMENTS VIEW