Case: T17DV00060
Case Details
Entered Date:
01/07/2017
Applicant:
NEW MANAGER JUAN CASTANEDA
Description:
COMMERCIAL FIRE
Outstanding Inspections
Case Number: T17DV00060
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/12/2017 | EMERGENCY CALL OUT | VALDEZ | Item closed | |
| 07/12/2017 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | VALDEZ | Item closed | |
| 07/12/2017 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VALDEZ | Item closed | |
| 07/12/2017 | NPO(PL)-PLUMBING SYSTEM & FX | VALDEZ | Item closed | |
| 07/12/2017 | NPO(DL)-DILAPIDATED STRUCTURE | VALDEZ | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T17DV00060
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/07/2017 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CALL OUT BY TFD: HOOD FIRE AT KFC, TFD STATED THAT THERE WAS FIRE IN AND ABOVE THE HOOD AROUND THE EXHAUST DUCT. THE HOOD IS ESTIMATE 16 FEET LONG WITH ONE 16" X16" EXHAUST DUCT, WHILE THE DROPPED DOWN CEILING TILES WERE REMOVED BY TFD, I SAW A CUT OUT IN THE CEILING FOR ANOTHER EXHAUST DUCT WHICH WAS COVERED UP. THE SIDE OF THE HOOD WHICH DOESN'T HAVE AN EXHAUST DUCT HAS (2) HOT HOLDING UNITS (OVEN WARMERS) UNDERNEATH. IM CONCERNED ABOUT ONLY ONE DUCT FOR THE ENTIRE HOOD SYSTEM. THE FRYERS WERE LEFT ON. THERE IS MC CABLE ABOVE THE HOOD AND AN OUTLET WITH A DUPLEX RECEPTACLE SATURATED WITH OIL BEHIND THE FRYERS. THE ANSUL SYSTEM DID NOT DEPLOY. THERE IS NO STRUCTURAL DAMAGE TO THE BUILDING. SWG DID SHUT THE GAS OFF. TEP DID LOCK OUT THE POWER. THERE IS DAMAGE TO THE CEILING TILES. THE 4 INTERIOR PANELS HAVE CODE VIOLATIONS, CIRCUIT BREAKERS WHICH ARE UNREADABL, DAMAGED AND NO LABELING ON THE PANELS. ONE CIRCUIT BREAKER HAS A HOMEMADE HANDLE TIE. THE FRONT DOOR TO THE BUILDING WERE FORCED OPEN, THE MANAGER DID SECURED THE BUILDING, THE BUILDING WAS CONDEMNED, PERMITS REQUIRED FOR REPAIRS TO THE HOOD SYSTEM, FIRE SYSTEM, ELECTRICAL AND GAS, SCHEDULE A 30 DAYS INSPECTION FOR THE AREA INSPECTOR |
| 07/12/2017 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | CURRENT PERMIT IS ON HOLD DUE TO EXCESSIVE WORK REQUIRED PER BUILDING OFFICIAL . BUILDING IS VACANT AND SECURED. CLOSE CASE |
Completed Activity Special Conditions
Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T17DV00060
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 01/27/2017 | CONTACTED BY PHONE |
| 01/07/2017 | CONTACTED IN PERSON |
| 01/27/2017 | CONTACTED BY EMAIL |
| 01/07/2017 | NOTICE AND ORDER ISSUED |
| 07/12/2017 | VIOLATION CLOSED |
| 01/07/2017 | CALLBACK |