Case: T17DV00023
Case Details
Entered Date:
01/03/2017
Applicant:
FABIOLA A DUENAS
Description:
PATIO FIRE AND ELECTRICAL VIOLATIONS
Outstanding Inspections
Case Number: T17DV00023
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/30/2017 | EMERGENCY CALL OUT | VIDAL | Item closed | |
| 03/30/2017 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VIDAL | Item closed | |
| 03/30/2017 | NPO(DL)-DILAPIDATED STRUCTURE | VIDAL | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T17DV00023
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/03/2017 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | THERE WAS DAMAGE TO THE WALL SIDING IN THE PATIO AREA CAUSE BY A FIRE FROM ADJACENT PROPERTY ADDRESSED AT 1347 E NEVADA. TUCSON FIRE DEPATMENT DID REMOVE THE DAMAGED WALL SIDING AND ALSO CUT THE ROOF SHEATHING. THE ELECTRICAL VIOLATIONS ON THE DOWNSTREAM PANEL ARE NOT AS A RESULT OF THE FIRE BUT AS FOLLOWS: THERE ARE MULTIPLE CONDUCTOR TERMINATIONS IN THE SAME TERMINAL LUG AT THE CIRCUIT BREAKER, NUETRAL BAR AND THE MAIN BUS. GROUNDS AND NEUTRALS ARE NOT SEPARATED. THE DEAD FRONT NOT INSTALLED AND HAS NO LABELING. MAIN PANEL HAS NO LABELING.FOLLOW UP DUE IN 30 DAYS FOR INSPECTOR VIDAL ALL DOCS AND PICS IN SIRE |
| 03/30/2017 | INSP - FOLLOW UP CODE ENFORCE | VIDAL | Approved | All the work has been completed and the permit has been issued, T17CM00483 on 1-19-17 and finaled on 2-14-17. The tenant has no other issues at this time and the case will be closed. Violation Abated, Close Case. RV. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T17DV00023
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
| Date | Name |
| 01/04/2017 | CONTACTED BY PHONE |
| 01/04/2017 | CONTACTED IN PERSON |
| 01/04/2017 | CONTACTED BY MAILING |
| 01/04/2017 | CONTACTED BY EMAIL |
| 01/04/2017 | NOTICE OF VIOLATION ISSUED |
| 03/30/2017 | VIOLATION CLOSED |
| 01/04/2017 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |