Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

12/07/2016

Applicant:

AZ QUALHOUSING LLC: ATTN YI TANG

Description:

HAZARDOUS ELECTRICAL

Outstanding Inspections

Case Number: T16DV08252
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
12/07/2016 EMERGENCY CALL OUT VALDEZ Item initialized
12/07/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item initialized
12/07/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV08252
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/07/2016 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved ELECTRICAL VIOLATIONS UNIT 14, EQUIPMENT DISCONNECT HAS MULTIPLE VIOLATIONS THERE ARE EXPOSED CABLES OUTSIDE OF THE ENCLOSURE AND ALSO BEING USED FOR BURIAL, THESE CABLES ARE NOT RATED FOR ITS USE THEY'RE INSTALLED IN A HAZARDOUS MANNER. THE ENCLOSURE HAS MISMATCHED BREAKERS WHICH AR NOT PROPERLY SEATED. THE ENCLOSURE IS A SQUARE D PANEL. THERE IS ONE CIRCUIT BREAKER 20 AMP WHICH HAS MULTIPLE CONDUCTORS ON ONE TAP. THERE ARE TWO SINGLE POLE BREAKERS BEING USED FOR ONE CIRCUIT NO HANDLE TIE. THERE IS NO DEAD FRONT, NO LABELING. THERE IS AN ENCLOSURE UNDERNEATH THE COOLER WITH TWO SINGLE POLE BREAKERS ALSO INSTALLED WITHOUT PERMITS AND A HAZARDOUS MANNER, WIRING IS EXPOSED THERE IS NO DEAD NOR A FRONT COVER TO THIS ENCLOSURE, PARK AT RISK FOR FIRE. ALL THE WORK DONE IS NOT APPROVED AND IS WORK WITHOUT PERMITS NOTICE AND ORDER WAS ISSUED ONSITE, THE MOBILE HOME WAS CONDEMNED UNFIT TO OCCUPY THERE ARE USING PVC WATER PIPE AS CONDUIT. ALL OF THE EQUIPMENT WAS TESTED AND ALL EQUIPMENT FOUND IN VIOLATION WAS ENERGIZED CITY OF TUCSON ACTION WAS TO TURN OFF ALL CIRCUIT BREAKERS IN THE EQUIPMENT DISCONNECT. THE ENCLOSURE WAS SECURED BY MANAGERS LOCK. A NOTICE OF VIOLATION WAS SIGNED BY MANAGER AND A PLACARD WAS POSTED ON THE UNIT WHICH READS UNFIT TO OCCUPY PERMITS ARE GOING TO BE REQUIRED FOR THE ELECTRICAL REPAIRS OVERALL: THE MODIFICATIONS TO THE EQUIPMENT DISCONNECT AND THE UNAPPROVED WIRING METHODS ARE HAZARDOUS AND PUT THE TENANTS AND THE PARK TENANTS AT RISK FOR FIRE DAMAGE.
04/20/2017 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved PERMIT T17CM02492 FINAL ON 4-13-2018 CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T16DV08252
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
12/07/2016 CONTACTED BY PHONE
12/07/2016 CONTACTED IN PERSON
12/08/2016 CONTACTED BY EMAIL
12/07/2016 NOTICE AND ORDER ISSUED
04/20/2017 VIOLATION CLOSED
12/07/2016 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
20161207_134735.JPG DOCUMENTS VIEW
20161207_134750.JPG DOCUMENTS VIEW
20161207_134755.JPG DOCUMENTS VIEW
20161207_134802.JPG DOCUMENTS VIEW
20161207_134807.JPG DOCUMENTS VIEW
20161207_141115.JPG DOCUMENTS VIEW
20161207_141120.JPG DOCUMENTS VIEW
20161207_141157.JPG DOCUMENTS VIEW
20161207_141223.JPG DOCUMENTS VIEW
20161207_141229.JPG DOCUMENTS VIEW
20161207_141321.JPG DOCUMENTS VIEW
20161207_142038.JPG DOCUMENTS VIEW
20161207_142228.JPG DOCUMENTS VIEW
20161207_142541.JPG DOCUMENTS VIEW
20161207_142936.JPG DOCUMENTS VIEW
118 E PRINCE RD.PDF DOCUMENTS VIEW
2016-12-07-14-07-51_AATSC.JPG DOCUMENTS VIEW
2016-12-07-14-08-12_AATSC.JPG DOCUMENTS VIEW