Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T16DV05606
Case Details
Entered Date:
09/15/2016
Applicant:
SCOTT PHILIP L B & HARY YOLANDA G CP/RS
Description:
COMMUNICATION CALLED THAT T.F.D. ON SITE WITH APARTMENT FIRE
Outstanding Inspections
Case Number: T16DV05606
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2016 | EMERGENCY CALL OUT | HOLLANDER | Item closed | |
| 12/06/2016 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | HOLLANDER | Item closed | |
| 12/06/2016 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | HOLLANDER | Item closed | |
| 12/06/2016 | NPO - SMOKE ALARMS | HOLLANDER | Item closed | |
| 12/06/2016 | NPO - OTHER | HOLLANDER | Item closed | |
| 12/06/2016 | NPO - WORK WITHOUT PERMIT | HOLLANDER | Item closed | |
| 12/06/2016 | NPO - INT. BUILDING MAINTENANC | HOLLANDER | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV05606
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2016 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | Recieved call from communication that T.F.D. on site with an apartment fire. Arrived and all the unit have cleared and the investigators are on site. Had a fire on the kitchen stove and burned the range hood over the stove, the cabinet over the stove, the drywall on the walls and ceilings and the smoke went into the living room area. The drywall was pulled down on the walls and ceilings to check for fire past the drywall. The light fixture was damaged in the fire and will need to be replaced. No other damage to the other units. The management on site and placed the tenant in another unit. They moved her bed and clothing to the other unit. The management signed the paper work and the power was turned off at the sub-panel in the bathroom due to not able to lock out the main breaker due to lacking the cover. The breaker is turned off at this time on the exterior of the unit. Did go over that a permit is required for the replacement of the drywall. Will check in 30 days. RV. |
| 12/06/2016 | INSP - FOLLOW UP CODE ENFORCE | HOLLANDER | Approved | Permit #T16CM07147 has been secured, inspected. At this time Code Enforcement does not have any further jurisdiction or authority. |
Completed Activity Special Conditions
Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T16DV05606
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 11/22/2016 | CONTACTED BY PHONE |
| 09/21/2016 | CONTACTED IN PERSON |
| 09/15/2016 | NOTICE OF VIOLATION ISSUED |
| 12/06/2016 | VIOLATION CLOSED |