Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING

Entered Date:

09/15/2016

Applicant:

SCOTT PHILIP L B & HARY YOLANDA G CP/RS

Description:

COMMUNICATION CALLED THAT T.F.D. ON SITE WITH APARTMENT FIRE

Outstanding Inspections

Case Number: T16DV05606
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
12/06/2016 EMERGENCY CALL OUT HOLLANDER Item closed
12/06/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT HOLLANDER Item closed
12/06/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX HOLLANDER Item closed
12/06/2016 NPO - SMOKE ALARMS HOLLANDER Item closed
12/06/2016 NPO - OTHER HOLLANDER Item closed
12/06/2016 NPO - WORK WITHOUT PERMIT HOLLANDER Item closed
12/06/2016 NPO - INT. BUILDING MAINTENANC HOLLANDER Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV05606
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/15/2016 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Recieved call from communication that T.F.D. on site with an apartment fire. Arrived and all the unit have cleared and the investigators are on site. Had a fire on the kitchen stove and burned the range hood over the stove, the cabinet over the stove, the drywall on the walls and ceilings and the smoke went into the living room area. The drywall was pulled down on the walls and ceilings to check for fire past the drywall. The light fixture was damaged in the fire and will need to be replaced. No other damage to the other units. The management on site and placed the tenant in another unit. They moved her bed and clothing to the other unit. The management signed the paper work and the power was turned off at the sub-panel in the bathroom due to not able to lock out the main breaker due to lacking the cover. The breaker is turned off at this time on the exterior of the unit. Did go over that a permit is required for the replacement of the drywall. Will check in 30 days. RV.
12/06/2016 INSP - FOLLOW UP CODE ENFORCE HOLLANDER Approved Permit #T16CM07147 has been secured, inspected. At this time Code Enforcement does not have any further jurisdiction or authority.

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T16DV05606
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
11/22/2016 CONTACTED BY PHONE
09/21/2016 CONTACTED IN PERSON
09/15/2016 NOTICE OF VIOLATION ISSUED
12/06/2016 VIOLATION CLOSED

Documents

File Name Document Type  
DSCN0740.JPG DOCUMENTS VIEW
DSCN0741.JPG DOCUMENTS VIEW
DSCN0742.JPG DOCUMENTS VIEW
DSCN0743.JPG DOCUMENTS VIEW
DSCN0744.JPG DOCUMENTS VIEW
DSCN0745.JPG DOCUMENTS VIEW
DSCN0746.JPG DOCUMENTS VIEW
DSCN0747.JPG DOCUMENTS VIEW
DSCN0748.JPG DOCUMENTS VIEW
DSCN0749.JPG DOCUMENTS VIEW
DSCN0750.JPG DOCUMENTS VIEW
DSCN0751.JPG DOCUMENTS VIEW
DSCN0752.JPG DOCUMENTS VIEW
NOV&ORDER_5606.PDF DOCUMENTS VIEW