Case: T16DV04099
Case Details
Entered Date:
07/06/2016
Applicant:
NEW CENTURY INVESTMENTS, LLC
Description:
ADDRESS IS 1513 UNIT B 1. LEAK IN THE KITCHEN THROUGH THE ROOF. ALSO IN UTILITY CLOSET. 2. NO SEALS ON WINDOWS THEY LEAKED AS WELL. 3. MOSQUITO INFESTATION ON PROPERTY DUE TO PUDDLES OF WATER. 4. ELECTICAL ISSUES. POWER GOING OUT INTERMTENT AND SPARKING AND LOOSE. 5. GUTTERS NOT ATTACHED PROPERLY AND ARE GLOGGED. 6. RODENT INFESTATION.
Case Violations
Case Number: T16DV04099
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date | Code Statue |
---|---|
07/29/2016 | T.C. Ch. 16, Sec. 16-13(e) EXTERIOR INSECT, RODENT AND ANIMAL CONTROL. All premises shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
07/29/2016 | T.C. Ch. 16, Sec. 16-12(a)(5) DECORATIVE FEATURES. All cornices, belt courses, corbels, trim, eaves, fascia, soffit, wall facings and similar decorative features shall be maintained in good repair, free of decay, rot or loose material, and have proper anchorage. |
07/29/2016 | T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
07/29/2016 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
07/29/2016 | T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration. |
08/02/2016 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
Outstanding Inspections
Case Number: T16DV04099
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/17/2016 | NPO(PL)-PLUMBING SYSTEM & FX | VINDIOLA | Item closed | |
10/17/2016 | NPO(DL)-DILAPIDATED STRUCTURE | VINDIOLA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV04099
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/29/2016 | INSP - INITIAL CODE ENFORCMENT | VINDIOLA | Approved | ADDRESS IS 1513 UNIT B 1. LEAK IN THE KITCHEN THROUGH THE ROOF. ALSO IN UTILITY CLOSET. 2. NO SEALS ON WINDOWS THEY LEAKED AS WELL. 3. MOSQUITO INFESTATION ON PROPERTY DUE TO PUDDLES OF WATER. 4. ELECTICAL ISSUES. POWER GOING OUT INTERMTENT AND Arrived on site already spoke to tenant and mananger over the phone before I arrived. Met with tenant and her friend Marty. Evidence of ground squirrels in the yard with mounds by the tree and front yard with holes. Rain gutters along front edge of home not properly secured and not at the right angle for water to drain. Roof line flashing along the front edge of the home is merely taped with aluminum and needs to be repaired with proper flashing. Also claims of mosquitoes with water ponding in the front yard at current did not see water ponding and did not see mosquitoes unable to move forward with that issue. Kitchen window shows signs of leakage with worn-out sheetrock at corner signs signs of rust and claims that water was in the channel. Move that is you to notice of violation also in kitchen under cabinet at corner sheetrock along with shows a hairline crack needs to be taped and painted. faceplate to outlet behind refrigerator in kitchen and another cracked outlet in dining room, outlet appears to be loose will need to be tightened or replaced. Living room area with outlets throughout need to be secured or replaced . Kids bedroom possibly loose Outlets please check both bedrooms for any cracked or loose Outlet or face covers. Carpet in kids bedroom not an issue at this time carpet in main bedroom also a non-issue at this time. Storage room in hallway to bedrooms ceiling appears to be leaking sheetrock damage to that ceiling area.. check smoke detector in front entry operational smoke detector in main hallway also operational smoke detector in bedroom master bedroom operational and smoke detector in kids bedroom also operational. Rear yard to find no workable space to the electrical panel electrical panel also lacks labeling for circuitry. A/C unit in window to rear bedroom blocking access in case of emergency, was taken down by tenant while I was on site, will not put in notice. Four holes along the back wall correction for holes along back wood siding to the property possibly woodpeckers. Mouse seen in kitchen area droppings on floor in kitchen area and pantry.. inspection was done with tenant and her friend Marty who were both on site |
10/17/2016 | INSP - FOLLOW UP CODE ENFORCE | VINDIOLA | Approved | Arrived on site to find, no one home looks to be vacant. Gutters in fornt were secured and holes in front yard and holes in back walls were abated, along with stoage in front of electrical panel and window a/c removed. Called and spoke to manager, states he is out of town however all was abated in the interior aswell. Will move to close out this case |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T16DV04099
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
08/03/2016 | CONTACTED BY MAILING |
08/02/2016 | NOTICE OF VIOLATION ISSUED |
10/17/2016 | VIOLATION CLOSED |