Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

06/16/2016

Applicant:

ENNABE PROPERTIES INC

Description:

EMERGENCY / UNITS 1102 & 1202 FLOODED

Outstanding Inspections

Case Number: T16DV03581
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
06/17/2016 NPO(PL)-PLUMBING SYSTEM & FX GOODMAN Item closed
06/17/2016 NPO - SMOKE ALARMS GOODMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV03581
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date Description Inspector Results Comments
06/15/2016 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MET WITH TFD WHO INFORMED ME THAT A HEAD IN THE FIRE SPRINKLER SYSTEM WAS BROKEN IN THE VACANT UNIT OF 1202. VISITED UNIT 1202 AND FOUND WATER THRU OUT THE FLOOR OF THE UNIT, AND UNIT WAS COMPLETELY VACANT, UNIT WAS NEWLY REMODELED. DOWNSTAIRS IN UNIT 1102 I FOUND A NEWLY REMODELED UNIT WITH WATER COMING THRU THE CEILING ONLY IN ONE SPOT, WATER WAS BEING CAUGHT IN BUCKETS BUT STILL ALOT OF WATER ON THE FLOOR. LOOKED AT THE BROKEN SPINKLER HEAD AND FOUND IT WAS ACTUALLY A PLUG IN THE LINE AND DID NOT APPEAR TO BE CORRECTLY INSTALLED. TFD THEN CALLED THEIR FIRE SUPPRESION INSPECTOR OUT TO THE PROPERTY, HE AGREED THE PLUG WAS NOT INSTALLED AND CHECKED THEIR FIRE SPRINKLER SYSTEM AND FOUND IT HAD BEEN TURNED OFF.MANAGER CONTACTED THE APTS FIRE SUPPRESION PERSON WHO WAS IN ROUTE FROM PHOENIX. TFD SPOKE WITH PROPERTY FIRE SUPPRESION PERSON, CONVERSATION SEEMED SKETCHING, CHECKED THE APTS. SYSTEM FOUND IT COULD HAVE BEEN OFF FOR AT LEAST ONE TO TWO WEEKS. AT THAT POINT TFD SERVED A ORDER TO ESTABLISH A FIRE WATCH AND THAT WAS SET UP FOR THE MANAGER AND MAINTANENCE PERSON. TFD ALSO REQUESTED THAT WILDCAT SUPPRESION COMPANY, THE LAST COMPANY TO CHECK THE SYSTEM BE CALLED TO CHECK AND RECHARGE THE SYSTEM. MANAGEMENT DID CALL WILDCAT, THEY WOULD BE OUT IN FORTY FIVE MINUTES AND TFD DECIDED THEY WOULD WAIT FOR WILDCAT TO GO OVER THE SYSTEM. IN THE MEAN TIME, MAINTANENCE HAD RETRACTED ALL WATER FROM BOTH UNITS. THE ONLY REPAIR REQUIRED AT THIS POINT WAS THE CEILING AREA 2 FT X 2FT. A NOV WAS NOT REQUIRED AS DRYWALL WAS REMOVED PRIOR TO MY LEAVING THE UNITS. OCCUPANT IN 1102 WAS PUT UP IN A MOTEL UNTIL UNIT COMPLETELY DRYED OUT. OCCUPANT WAS OK WITH THAT DECISION. ONLY ONE LIGHT FIXTURE WAS AFFECTED BY THE WATER. NOV WAS NOT REQUIRED. ALL PROPER ACTIONS WERE ENFORCED BY TFD. NO VIOLATIONS / CLOSE CASE.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T16DV03581
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
06/17/2016 VIOLATION CLOSED

Documents

File Name Document Type  
03581.PDF DOCUMENTS VIEW