Case: T16DV03506
Case Details
Entered Date:
06/13/2016
Applicant:
DUNG THI & HAROLD NGUYEN JT/RS
Description:
Electric work without permit last week causing a short and electric shock from the front light switch.
Case Violations
Case Number: T16DV03506
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 2
| Violation Date | Code Statue |
|---|---|
| 06/14/2016 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 06/20/2016 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T16DV03506
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/18/2016 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | VINDIOLA | Item closed | |
| 07/18/2016 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VINDIOLA | Item closed | |
| 07/18/2016 | NPO - WORK WITHOUT PERMIT | VINDIOLA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV03506
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/13/2016 | INSP - INITIAL CODE ENFORCMENT | VINDIOLA | Approved | Compliant:Electric work without permit last week causing a short and electric shock from the front light switch. Arrived on site with Inspector Hollander TEP already on site, TEP check the box and meter all was fine, Inspector Hollander indentified the system as a two wire system from box. Made contact with tenant states when he touched the light switch to front porch light and front door was shocked. Inspector tested striker plate and got a reading as it being powered when he touches light switch. Eliminated hazzard by removing bottom screw to plate however stiker plate and door was still operational. Checke sub panel in closet to master bedroom all was in order, No smoke detectors in bedrooms or hallway leading to bedrooms. Bedrooms had newer outlets but were 3 wire outlets on a 2 wire system, grounded receptacles on non grounded system in both bedrooms. New outlets again 3 wires in bothroom and kitchen with out being GFCI. Newer gas furnace see in unit without permit, will get with supervision before nov is given out. Again hazzard eleminated before we left the site |
| 07/18/2016 | INSP - FOLLOW UP CODE ENFORCE | VINDIOLA | Approved | arrived on site and met with sister of the owner, states electician removed the door casing and fixed wire in the door case. New smoke detectors installed in all bedrooms invoice was given for all the work will move to close out this case. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T16DV03506
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 06/13/2016 | CONTACTED BY PHONE |
| 06/27/2016 | CONTACTED BY MAILING |
| 06/20/2016 | NOTICE OF VIOLATION ISSUED |
| 07/18/2016 | VIOLATION CLOSED |