Description:

Electrical outlets sparking in living room, living room floor is cracking and sinking. Furnace has wires hanging.

Outstanding Inspections

Case Number: T16DV03450
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
11/30/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item closed
11/30/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item closed
11/30/2016 NPO(DL)-DILAPIDATED STRUCTURE VALDEZ Item closed
11/30/2016 NPO - WORK WITHOUT PERMIT VALDEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV03450
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/18/2016 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL-OUT BY TUCSON FIRE: INSPECTED THE INTERIOR OF THE DWELLING UNIT FOUND GFCI RECEPTACLE IN THE KITCHEN WITH BURN MARKS. TENANT STATES THAT THERE WAS AN ARC SO SHE CALLED THE FIRE DEPARTMENT, SHE STATES THAT THE ENTIRE ELECTRICAL SYSTEM IN THE HOUSE IS DANGEROUS. I INSPECTED THE INTERIOR OF THE ROOMS AND FOUND OTHER OUTLETS WITH MISSING COVER PLATES AND DAMAGED COVER PLATES. I DID INSPECTION OF THE MAIN SERVICE WHICH IS A 40 AMP DISCONNECT WITH THREE OTHER 30 AMP FUSE BOXES WHICH HAVE BEEN ADDED OVER TIME. I FOUND A 220V DRYER CONNECTED TO A 110 OUTLET. THE TENANT AND STATES OF THE DRYER DOESN'T WORK BECAUSE THE FUSES BLOW. THE DWELLING UNIT WAS CONDEMNED DUE TO FAULTY ELECTRICAL AND UNPERMITTED ELECTRICAL WORK INSIDE THE MAIN DISCONNECT AND THE OTHER FUSE BOXES. TERMINAL LUGS ON THE MAIN DISCONNECT AND OTHER FUSE BOXES HAVE MULTIPLE CONDUCTORS.THE DWELLING UNIT WAS CONDEMNED, TEP DID SHUT THE POWER OFF TO THE MAIN DISCONNECT. SCHEDULE A 30 DAYS FOLLOW UP INSPECTION.
11/30/2016 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved PERMIT T16CM04791 WAS FINAL CLOSE CASE

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T16DV03450
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
06/17/2016 CONTACTED BY PHONE
06/22/2016 CONTACTED IN PERSON
12/01/2016 VIOLATION CLOSED
06/22/2016 CALLBACK

Documents

File Name Document Type  
1847 S OLSEN.PDF DOCUMENTS VIEW
20160618_145050.JPG DOCUMENTS VIEW
20160618_134143.JPG DOCUMENTS VIEW
20160618_134218.JPG DOCUMENTS VIEW
20160618_134258.JPG DOCUMENTS VIEW
20160618_134313.JPG DOCUMENTS VIEW
20160618_134339.JPG DOCUMENTS VIEW
20160618_134348.JPG DOCUMENTS VIEW
20160618_134411.JPG DOCUMENTS VIEW
20160618_134420.JPG DOCUMENTS VIEW
20160618_134518.JPG DOCUMENTS VIEW
20160618_134542.JPG DOCUMENTS VIEW
20160618_134643.JPG DOCUMENTS VIEW
20160618_134652.JPG DOCUMENTS VIEW
20160618_134659.JPG DOCUMENTS VIEW
20160618_134703.JPG DOCUMENTS VIEW
20160618_134737.JPG DOCUMENTS VIEW
20160618_135506.JPG DOCUMENTS VIEW
20160618_135623.JPG DOCUMENTS VIEW
20160618_135629.JPG DOCUMENTS VIEW
20160618_135646.JPG DOCUMENTS VIEW
20160618_135655.JPG DOCUMENTS VIEW
20160618_140122.JPG DOCUMENTS VIEW
20160618_144939.JPG DOCUMENTS VIEW
20160618_144955.JPG DOCUMENTS VIEW
20160618_144958.JPG DOCUMENTS VIEW
20160618_145009.JPG DOCUMENTS VIEW
20160618_145047.JPG DOCUMENTS VIEW