Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

05/13/2016

Applicant:

PHELPS WESTERN INVESTMENTS LP

Description:

FLOOR IS DILAPITATING IN MASTER FRONT PORTION OF BEDROOM FOUNDATION IS DETERIOATING INTO A WHOLE THAT IS UNDERNEATH THE HOUSE AS A RESULT OF PAST LEAKS FLOOR SINKING IN THE LIVING ROOM AND BED ROOM

Outstanding Inspections

Case Number: T16DV02957
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
05/24/2016 NPO(PL)-PLUMBING SYSTEM & FX PUMPHREY Item closed
05/24/2016 NPO(DL)-DILAPIDATED STRUCTURE PUMPHREY Item closed
05/24/2016 NPO - INT. BUILDING MAINTENANC PUMPHREY Item closed
07/22/2016 NPO - WORK WITHOUT PERMIT PUMPHREY Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV02957
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/23/2016 INSP - INITIAL CODE ENFORCMENT PUMPHREY Approved Met complainant at unit; unit was vacant as she was moving out and was no longer intending on occupying unit. The wood plank flooring throughout unit was in acceptable condition and was not dilapidated or sinking; the hole referred to in complaint is a crawl space access in the bedroom closet; this area did not have leaks or a sewer smell; small crack in kitchen ceiling along with small cracks in exterior foundation area appear as normal for a structure of this age (1940's) and does not appear to indicate a hazard. Photos taken. There was a newly installed gas heater furnace in living room (turned off) that did not have permits for installation; gas water heater at rear of exterior had venting that did not meet code and did not rise above roof line. NOV will be issued for furnace and heater only.

Outstanding Case Activity Conditions

Date Name Approved
05/24/2016 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T16DV02957
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
06/06/2016 CONTACTED BY PHONE
05/25/2016 CONTACTED BY MAILING
05/13/2016 CONTACTED BY EMAIL
05/24/2016 NOTICE OF VIOLATION ISSUED
07/22/2016 VIOLATION CLOSED
07/22/2016 RESEARCH

Documents

File Name Document Type  
02957.PDF DOCUMENTS VIEW