Case: T16DV02865
Case Details
Entered Date:
05/10/2016
Applicant:
LOS ALTOS APARTMENTS LLC
Description:
CAR IN TO A COMMERCIAL BUILDING
Outstanding Inspections
Case Number: T16DV02865
Case Status: COMPLIAN
Case Description: CAR THROUGH COMMERCIAL BUILDIN
Total Outstanding Inspections - 7
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/16/2016 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | HARO | Item closed | |
08/16/2016 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | HARO | Item closed | |
08/16/2016 | NPO(PL)-PLUMBING SYSTEM & FX | HARO | Item closed | |
08/16/2016 | NPO(PL)-GAS SUPPLY/CONNECT | HARO | Item closed | |
08/16/2016 | NPO(PL)-SEWAGE DISPOSAL (SYS) | HARO | Item closed | |
08/16/2016 | NPO(DL)-DILAPIDATED STRUCTURE | HARO | Item closed | |
08/16/2016 | NPO - OTHER | HARO | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV02865
Case Description: CAR THROUGH COMMERCIAL BUILDIN
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/07/2016 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISTED SITE, MET WITH TPD OFFICERS, MANAGER SUSAN CARVER, MAINTANENECE CEASAR HERNANDEZ AND OCCUPANT MICHAEL SURDICK. FINDINGS AS FOLLOWS: > CAR ENTERED S/W CORNER OF 2 STORY APT COMPLEX. >CAR DISPLACED CORNER STUDS, THE NEXT FIVE FIELD STUDS THAT CARY THE 2ND FLOOR. > APPROX 8 FT X 8 FT OF STUCCO DAMAGE > APPROX 8FT X 10 FT OF DAMAGED DRYWALL > 6-0 X 6-8 REAR SLIDING GLASS DOOR DAMAGED. > (2) INTERIOR OUTLETS AFFECTED BUT NOT DAMAGED, WIRING STRETCHED. ONE EXTERIOR OUTLET AFFECTED BUT NOT DAMAGED. >STUDS WERE PLACED BACK ONTO THE BOTTOM PLATE AND EXTERIOR SHEARED BY BOARD UP COMPANY WITH 5/8" PLYWOOD AND INTERIOR SECURED WITH 1/2" OSB. > CORNER WAS REBUILT FOR THE STRENGTH TO CARRY THE ABOVE UNIT. THERE IS NO DANGER OF FAILURE BELOW. >THERE IS NO ELECTRICAL ISSUES, JUST STRETCHED WIRING BECAUSE OF DISPLACED STUDS, NO TRIPPED BREAKERS. >NOV ISSUED TO MANAGER SUSAN CARVER FOR PERMITS REQUIRED. > OK FOR TENANT TO STAY IN UNIT. WILL NEED TO MAKE ARRANGEMENTS TO ALLOW WORKERS TO COMPLETE NEW WORK. >BOARD UP COMPLETED BY DAMIEN, ARCAIDAN INDUSTRIES |
08/16/2016 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | WORK COMPLETED UNDER PERMIT TI6CM03582, COMPLIANCE CLOSE CASE. |
Completed Activity Special Conditions
Case Description - CAR THROUGH COMMERCIAL BUILDIN
Case Number - T16DV02865
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
05/10/2016 | CONTACTED BY MAILING |
05/10/2016 | NOTICE OF VIOLATION ISSUED |
11/15/2016 | VIOLATION CLOSED |