Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T16DV02865
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/07/2016 | INSP - INITIAL CODE ENFORCMENT | Approved | VISTED SITE, MET WITH TPD OFFICERS, MANAGER SUSAN CARVER, MAINTANENECE CEASAR HERNANDEZ AND OCCUPANT MICHAEL SURDICK. FINDINGS AS FOLLOWS: > CAR ENTERED S/W CORNER OF 2 STORY APT COMPLEX. >CAR DISPLACED CORNER STUDS, THE NEXT FIVE FIELD STUDS THAT CARY THE 2ND FLOOR. > APPROX 8 FT X 8 FT OF STUCCO DAMAGE > APPROX 8FT X 10 FT OF DAMAGED DRYWALL > 6-0 X 6-8 REAR SLIDING GLASS DOOR DAMAGED. > (2) INTERIOR OUTLETS AFFECTED BUT NOT DAMAGED, WIRING STRETCHED. ONE EXTERIOR OUTLET AFFECTED BUT NOT DAMAGED. >STUDS WERE PLACED BACK ONTO THE BOTTOM PLATE AND EXTERIOR SHEARED BY BOARD UP COMPANY WITH 5/8" PLYWOOD AND INTERIOR SECURED WITH 1/2" OSB. > CORNER WAS REBUILT FOR THE STRENGTH TO CARRY THE ABOVE UNIT. THERE IS NO DANGER OF FAILURE BELOW. >THERE IS NO ELECTRICAL ISSUES, JUST STRETCHED WIRING BECAUSE OF DISPLACED STUDS, NO TRIPPED BREAKERS. >NOV ISSUED TO MANAGER SUSAN CARVER FOR PERMITS REQUIRED. > OK FOR TENANT TO STAY IN UNIT. WILL NEED TO MAKE ARRANGEMENTS TO ALLOW WORKERS TO COMPLETE NEW WORK. >BOARD UP COMPLETED BY DAMIEN, ARCAIDAN INDUSTRIES |