Case: T16DV02865

Parcel: 10713261A


Addresses:

2525 N LOS ALTOS AV


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T16DV02865

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
05/07/2016 INSP - INITIAL CODE ENFORCMENT Approved VISTED SITE, MET WITH TPD OFFICERS, MANAGER SUSAN CARVER, MAINTANENECE CEASAR HERNANDEZ AND OCCUPANT MICHAEL SURDICK. FINDINGS AS FOLLOWS:
> CAR ENTERED S/W CORNER OF 2 STORY APT COMPLEX.
>CAR DISPLACED CORNER STUDS, THE NEXT FIVE FIELD STUDS THAT CARY THE 2ND FLOOR.
> APPROX 8 FT X 8 FT OF STUCCO DAMAGE
> APPROX 8FT X 10 FT OF DAMAGED DRYWALL
> 6-0 X 6-8 REAR SLIDING GLASS DOOR DAMAGED.
> (2) INTERIOR OUTLETS AFFECTED BUT NOT DAMAGED, WIRING STRETCHED. ONE EXTERIOR OUTLET AFFECTED BUT NOT DAMAGED.
>STUDS WERE PLACED BACK ONTO THE BOTTOM PLATE AND EXTERIOR SHEARED BY BOARD UP COMPANY WITH 5/8" PLYWOOD AND INTERIOR SECURED WITH 1/2" OSB.
> CORNER WAS REBUILT FOR THE STRENGTH TO CARRY THE ABOVE UNIT. THERE IS NO DANGER OF FAILURE BELOW.
>THERE IS NO ELECTRICAL ISSUES, JUST STRETCHED WIRING BECAUSE OF DISPLACED STUDS, NO TRIPPED BREAKERS.
>NOV ISSUED TO MANAGER SUSAN CARVER FOR PERMITS REQUIRED.
> OK FOR TENANT TO STAY IN UNIT. WILL NEED TO MAKE ARRANGEMENTS TO ALLOW WORKERS TO COMPLETE NEW WORK.
>BOARD UP COMPLETED BY DAMIEN, ARCAIDAN INDUSTRIES