Case Details

Status:

COMPLIAN

Type:

CAR THROUGH RESIDENTIAL BUILDI

Entered Date:

01/19/2016

Applicant:

WATERFALL INVESTMENTS LLC

Description:

COMMUNICATION CALLED THAT T.F.D. ON SITE WITH CAR THRU-BUILDING, ALARM #F160150186

Outstanding Inspections

Case Number: T16DV00224
Case Status: COMPLIAN
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Outstanding Inspections - 9
End Date Description Inspector Results Comments
02/05/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT VIDAL Item closed
02/05/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX VIDAL Item closed
02/05/2016 NPO(PL)-WATER HEATERS VIDAL Item closed
02/05/2016 NPO - EGRESS VIDAL Item closed
02/05/2016 NPO - REFUSE/TRASH/DEBRIS VIDAL Item closed
02/05/2016 NPO - OTHER VIDAL Item closed
02/05/2016 NPO - EXT. BUILDING MAINTENANC VIDAL Item closed
02/05/2016 NPO - WORK WITHOUT PERMIT VIDAL Item closed
02/05/2016 NPO - INT. BUILDING MAINTENANC VIDAL Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV00224
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/15/2016 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Received call from communication that T.F.D. on site with a car through building. Arrived and the fire units were on scene checking on the vehicle. T.P.D. on site checking if the vehicle could be pulled out. The vehicle was in the kitchen area with the front tires on the exterior wall location. The wood frame wall with foam and 1-coat system stucco with drywall on the interior was pushed in with the wood studs broken. There was a metal corner brace in the wall that was loose and removed. The vehicle was wedged against the bearing wall in the rear of the building. The wall that was hit was non-bearing. The wood studs were removed with the stucco to remove the vehilce. The owner of the building called a contractor to cover the opening with a board up. The electrical was turned off at the main breaker on the exterior panel and placed a City of Tucson lock. T.E.P. was not able to come to the site due to an outage. Did call communication to cancell the T.E.P. call due to leaving the site. The tenants did go to another location to stay. Did do the posting of "Do Not Enter"on the front window. Took pictures and had the owner sign the paper work. Once the contractor secured the building left the site. Will check in 30 days. RV.
02/05/2016 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved Received call that the lock on the breaker needs to be removed due to the work has been completed. The permit has been issued, T16CM00499 on 1-22-16 and finaled on 2-5-16. At this time the case will be closed and the lock was removed from the breaker. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - CAR THROUGH RESIDENTIAL BUILDI
Case Number - T16DV00224
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
11/15/2016 VIOLATION CLOSED

Documents

File Name Document Type  
PICTURE 2149.JPG DOCUMENTS VIEW
PICTURE 2120.JPG DOCUMENTS VIEW
PICTURE 2121.JPG DOCUMENTS VIEW
PICTURE 2122.JPG DOCUMENTS VIEW
PICTURE 2123.JPG DOCUMENTS VIEW
PICTURE 2124.JPG DOCUMENTS VIEW
PICTURE 2125.JPG DOCUMENTS VIEW
PICTURE 2126.JPG DOCUMENTS VIEW
PICTURE 2127.JPG DOCUMENTS VIEW
PICTURE 2128.JPG DOCUMENTS VIEW
PICTURE 2129.JPG DOCUMENTS VIEW
PICTURE 2130.JPG DOCUMENTS VIEW
PICTURE 2131.JPG DOCUMENTS VIEW
PICTURE 2132.JPG DOCUMENTS VIEW
PICTURE 2133.JPG DOCUMENTS VIEW
PICTURE 2134.JPG DOCUMENTS VIEW
PICTURE 2135.JPG DOCUMENTS VIEW
PICTURE 2136.JPG DOCUMENTS VIEW
PICTURE 2137.JPG DOCUMENTS VIEW
PICTURE 2138.JPG DOCUMENTS VIEW
PICTURE 2139.JPG DOCUMENTS VIEW
PICTURE 2140.JPG DOCUMENTS VIEW
PICTURE 2141.JPG DOCUMENTS VIEW
PICTURE 2142.JPG DOCUMENTS VIEW
PICTURE 2143.JPG DOCUMENTS VIEW
PICTURE 2144.JPG DOCUMENTS VIEW
PICTURE 2145.JPG DOCUMENTS VIEW
PICTURE 2146.JPG DOCUMENTS VIEW
PICTURE 2147.JPG DOCUMENTS VIEW
PICTURE 2148.JPG DOCUMENTS VIEW
3521 E. WATER NOVS AND DAMAGE REPORTS.PDF DOCUMENTS VIEW