Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES
Address:

Entered Date:

12/10/2015

Applicant:

NORTH OF THE RIVER INVESTMENTS LLC, ATTN: ANN BOYCE

Description:

This is an apartment complex. This property is > uninhabitable and has people living in units with boarded windows. It is > becoming an hazard to the areas surrounding it. There is no power running to > most of the units that have occupants.

Case Violations

Case Number: T15DV09539
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 3
Violation Date Code Statue
12/14/2015 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.
12/15/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
12/15/2015 T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly.

Outstanding Inspections

Case Number: T15DV09539
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
12/14/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Notice of violation
12/14/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Notice of violation
12/14/2015 NPO - REFUSE/TRASH/DEBRIS VALDEZ Notice of violation
12/14/2015 NPO - BOARDING EXCEEDING 180 D VALDEZ Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV09539
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/11/2015 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved ONSITE INSPECTION: THERE ARE OVER 20 VACANT UNITS THAT ARE BOARDED. MANAGEMENT IS WORKING ON THE UNITS. BELOW ARE THE INFRACTIONS TO BE ABATED. THERE IS A HAND GUARD NEXT TO UNIT 54 THAT IS MISSING HARDWARE AND IS NOT CONNECTED TO THE BUILDING. THERE IS DAMAGED TO THE DECKING IN FRONT OF UNITS 54, 70, 43 UNIT 20 HAS A TENANT LIVING WITHOUT POWER. TEP STATED THAT THE METER WAS TAMPERED WITH, NOW TEP REQUIRES THE CITY OF TUCSON PERMIT FOR A RECONNECT. THE WESTSIDE LAUNDRY ROOM HAS CONDUIT NOT PROPERLY SECURED AND EXPOSED WIRING. THE EASTSIDE LAUNDRY ROOM HAS JUNCTION BOXES WITH MISSING COVERS AND EXPOSED WIRING. UNIT 29 HAS AN EXTENSION CORD THAT WAS SLICED AND CONNECTED TO THE OUTDOOR LIGHT FIXTURE. UNIT 40 HAS A POWER STRIP THAT HAS BEEN SLICE INTO THE OUTDOOR LIGHT FIXTURE. UNIT 1 HAS AN OUTDOOR RECEPTACLE OUTLET WITH A MISSING OUTDOOR COVER. UNIT 11 HAS FRONT BROKEN WINDOW THIS UNIT IS OCCUPIED. UNIT 51, 41 LIGHT FIXTURE'S ARE UNSECURED. UNITS 15 16 17 52 53 54 HAVE LIGHT FIXTURES WITH EXPOSED WIRING. UNIT'S 54, 69, 71 HAS A BROKEN WINDOW. UNIT 61 THE FRONT WINDOW IS MISSING AND THE REAR GLASS SLIDER IS BROKEN. UNIT 60 HAS A MISSING LIGHT FIXTURE COVER. UNIT 3 LIGHT FIXTURE NEEDS REPAIR.
02/18/2016 INSP - FOLLOW UP CODE ENFORCE VINDIOLA Approved ARRIVED ON SITE FOR FOLLOW ALONG WITH INSPECTOR J. VALDEZ, FOUND ALL VIOLATIONS NOTED IN NOTICE OF VIOLATION WERE ALL ABATED TO INCLUDE: HANDRAILS - SECURED, BROKEN WINDOWS REPAIRED, UNSECURED WIRING THROUGHOUT ABATED, UNIT 20 HAD PROPER METERING SYSTEM AND WAS OPERATIONAL, AND DECKING IN SEVERAL AREAS WERE REPAIRED. MET WITH OWNER OF THE PROPERTY AND WILL MOVE TO CLOSE OUT THIS CASE.

Outstanding Case Activity Conditions

Date Name Approved
12/14/2015 2012 INTERNATIONAL BUILDING CODE CHAPTER 16 - STRUCTURAL DESIGN 1607.8 LOADS ON HANDRAILS, GUARDS, GRAB BARS, SEATS AND VEHICLE BARRIERS. HANDRAILS, GUARDS, GRAB BARS, ACCESSIBLE SEATS, ACCESSIBLE BENCHES AND VEHICLE BARRIERS SHALL BE DESIGNED AND CONSTRUCTED TO THE STRUCTURAL LOADING CONDITIONS SET FORTH IN THIS SECTION. 1607.8.1 HANDRAILS AND GUARDS. HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESIST A LINEAR LOAD OF 50 POUNDS PER LINEAR FOOT (PLF) (0.73 KN/M) IN ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7. GLASS HANDRAIL ASSEMBLIES AND GUARDS SHALL ALSO COMPLY WITH SECTION 2407. EXCEPTIONS: 1. FOR ONE- AND TWO-FAMILY DWELLINGS, ONLY THE SINGLE CONCENTRATED LOAD REQUIRED BY SECTION 1607.8.1.1 SHALL BE APPLIED. 2. IN GROUP I-3, F, H AND S OCCUPANCIES, FOR AREAS THAT ARE NOT ACCESSIBLE TO THE GENERAL PUBLIC AND THAT HAVE AN OCCUPANT LOAD LESS THAN 50, THE MINIMUM LOAD SHALL BE 20 POUNDS PER FOOT (0.29 KN/M). 1607.8.1.1 CONCENTRATED LOAD. HANDRAILS AND GUARDS SHALL ALSO BE DESIGNED TO RESIST A CONCENTRATED LOAD OF 200 POUNDS (0.89 KN) IN ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7. Not Approved

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T15DV09539
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
12/10/2015 CONTACTED BY PHONE
12/15/2015 CONTACTED BY MAILING
12/10/2015 CONTACTED BY EMAIL
12/15/2015 NOTICE OF VIOLATION ISSUED
02/19/2016 VIOLATION CLOSED