Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T15DV09539

Parcel: 130171870


Addresses:

4141 E 29TH ST


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T15DV09539

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
12/11/2015 INSP - INITIAL CODE ENFORCMENT Approved ONSITE INSPECTION: THERE ARE OVER 20 VACANT UNITS THAT ARE BOARDED. MANAGEMENT IS WORKING ON THE UNITS.
BELOW ARE THE INFRACTIONS TO BE ABATED.

THERE IS A HAND GUARD NEXT TO UNIT 54 THAT IS MISSING HARDWARE AND IS NOT CONNECTED TO THE BUILDING.

THERE IS DAMAGED TO THE DECKING IN FRONT OF UNITS 54, 70, 43

UNIT 20 HAS A TENANT LIVING WITHOUT POWER. TEP STATED THAT THE METER WAS TAMPERED WITH, NOW TEP REQUIRES THE CITY OF TUCSON PERMIT FOR A RECONNECT.

THE WESTSIDE LAUNDRY ROOM HAS CONDUIT NOT PROPERLY SECURED AND EXPOSED WIRING.

THE EASTSIDE LAUNDRY ROOM HAS JUNCTION BOXES WITH MISSING COVERS AND EXPOSED WIRING.

UNIT 29 HAS AN EXTENSION CORD THAT WAS SLICED AND CONNECTED TO THE OUTDOOR LIGHT FIXTURE.

UNIT 40 HAS A POWER STRIP THAT HAS BEEN SLICE INTO THE OUTDOOR LIGHT FIXTURE.

UNIT 1 HAS AN OUTDOOR RECEPTACLE OUTLET WITH A MISSING OUTDOOR COVER.

UNIT 11 HAS FRONT BROKEN WINDOW THIS UNIT IS OCCUPIED.

UNIT 51, 41 LIGHT FIXTURE'S ARE UNSECURED.

UNITS 15 16 17 52 53 54 HAVE LIGHT FIXTURES WITH EXPOSED WIRING.

UNIT'S 54, 69, 71 HAS A BROKEN WINDOW.

UNIT 61 THE FRONT WINDOW IS MISSING AND THE REAR GLASS SLIDER IS BROKEN.

UNIT 60 HAS A MISSING LIGHT FIXTURE COVER.

UNIT 3 LIGHT FIXTURE NEEDS REPAIR.