Case Details

Status:

REFERRED

Type:

MULTIPLE TYPES

Entered Date:

10/06/2015

Applicant:

ELITE HOSPITALITY LLC

Description:

REAR ENTRANCE STAIRWELL DOOR IS BLOCKED OPEN AND HAS A BROKEN WINDOW. ALL STAIRWELL DOORS ARE BEING PROPPED OPEN.

Outstanding Inspections

Case Number: T15DV07613
Case Status: REFERRED
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 11
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
10/07/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT VIDAL Item closed
10/07/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX VIDAL Item closed
10/07/2015 NPO(PL)-PLUMBING SYSTEM & FX VIDAL Item closed
10/07/2015 NPO(PL)-GAS SUPPLY/CONNECT VIDAL Item closed
10/07/2015 NPO(PL)-WATER HEATERS VIDAL Item closed
10/07/2015 NPO - EGRESS VIDAL Item closed
10/07/2015 NPO - OTHER VIDAL Item closed
10/07/2015 NPO - EXT. BUILDING MAINTENANC VIDAL Item closed
10/07/2015 NPO - WORK WITHOUT PERMIT VIDAL Item closed
10/07/2015 NPO - INT. BUILDING MAINTENANC VIDAL Item closed

Completed Inspections

Case Status: REFERRED
Case Number: T15DV07613
Case Description: MULTIPLE TYPES
Total Completed Inspections - 1
End Date Description Inspector Results Comments
10/07/2015 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Met with the manager of the property and went over that the call came in for doors being propped opened in the corridors. Did do an inspection on all the doors of the corridors on 3-floors. Did find some doors not able to open due to the closers were jambed or stuck or had to be forced opened. Doors through out had stoppers on the bottom of the doors or wedged with cardboard or items to hold the doors opened. The exterior light fixtures are missing globes or the fixture are loose and not secured properly. Some of the doors have been changed from original on the exterior doors with glass doors. Some of the glass has been changed in the doors in the corridors and are lacking wire in the glass and found no labels for safety or tempered glass. Have some ceiling tiles that are missing or brokened through out in the corridors. Did have a meeting room where the ceiling needs to be checked if the tie wires are loose or if they are fastened due to shows where not even with the other parts of the ceiling. Will need to meet with Tucson Fire to Review this case with them. RV.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T15DV07613
Case Status: REFERRED
Total Completed Case Activity Conditions: 2
Date Name
02/23/2016 CONTACTED IN PERSON
10/04/2016 VIOLATION CLOSED

Documents

File Name Document Type  
PICTURE 1623.JPG DOCUMENTS VIEW
PICTURE 1558.JPG DOCUMENTS VIEW
PICTURE 1559.JPG DOCUMENTS VIEW
PICTURE 1560.JPG DOCUMENTS VIEW
PICTURE 1561.JPG DOCUMENTS VIEW
PICTURE 1562.JPG DOCUMENTS VIEW
PICTURE 1563.JPG DOCUMENTS VIEW
PICTURE 1564.JPG DOCUMENTS VIEW
PICTURE 1565.JPG DOCUMENTS VIEW
PICTURE 1566.JPG DOCUMENTS VIEW
PICTURE 1567.JPG DOCUMENTS VIEW
PICTURE 1568.JPG DOCUMENTS VIEW
PICTURE 1569.JPG DOCUMENTS VIEW
PICTURE 1570.JPG DOCUMENTS VIEW
PICTURE 1571.JPG DOCUMENTS VIEW
PICTURE 1572.JPG DOCUMENTS VIEW
PICTURE 1573.JPG DOCUMENTS VIEW
PICTURE 1574.JPG DOCUMENTS VIEW
PICTURE 1575.JPG DOCUMENTS VIEW
PICTURE 1576.JPG DOCUMENTS VIEW
PICTURE 1577.JPG DOCUMENTS VIEW
PICTURE 1578.JPG DOCUMENTS VIEW
PICTURE 1579.JPG DOCUMENTS VIEW
PICTURE 1580.JPG DOCUMENTS VIEW
PICTURE 1581.JPG DOCUMENTS VIEW
PICTURE 1582.JPG DOCUMENTS VIEW
PICTURE 1583.JPG DOCUMENTS VIEW
PICTURE 1584.JPG DOCUMENTS VIEW
PICTURE 1585.JPG DOCUMENTS VIEW
PICTURE 1586.JPG DOCUMENTS VIEW
PICTURE 1587.JPG DOCUMENTS VIEW
PICTURE 1588.JPG DOCUMENTS VIEW
PICTURE 1589.JPG DOCUMENTS VIEW
PICTURE 1590.JPG DOCUMENTS VIEW
PICTURE 1591.JPG DOCUMENTS VIEW
PICTURE 1592.JPG DOCUMENTS VIEW
PICTURE 1593.JPG DOCUMENTS VIEW
PICTURE 1594.JPG DOCUMENTS VIEW
PICTURE 1595.JPG DOCUMENTS VIEW
PICTURE 1596.JPG DOCUMENTS VIEW
PICTURE 1597.JPG DOCUMENTS VIEW
PICTURE 1598.JPG DOCUMENTS VIEW
PICTURE 1599.JPG DOCUMENTS VIEW
PICTURE 1600.JPG DOCUMENTS VIEW
PICTURE 1601.JPG DOCUMENTS VIEW
PICTURE 1602.JPG DOCUMENTS VIEW
PICTURE 1603.JPG DOCUMENTS VIEW
PICTURE 1604.JPG DOCUMENTS VIEW
PICTURE 1609.JPG DOCUMENTS VIEW
PICTURE 1610.JPG DOCUMENTS VIEW
PICTURE 1611.JPG DOCUMENTS VIEW
PICTURE 1612.JPG DOCUMENTS VIEW
PICTURE 1613.JPG DOCUMENTS VIEW
PICTURE 1614.JPG DOCUMENTS VIEW
PICTURE 1615.JPG DOCUMENTS VIEW
PICTURE 1616.JPG DOCUMENTS VIEW
PICTURE 1617.JPG DOCUMENTS VIEW
PICTURE 1618.JPG DOCUMENTS VIEW
PICTURE 1619.JPG DOCUMENTS VIEW
PICTURE 1620.JPG DOCUMENTS VIEW
PICTURE 1621.JPG DOCUMENTS VIEW
PICTURE 1622.JPG DOCUMENTS VIEW