Case: T15DV05149
Case Details
Entered Date:
07/15/2015
Applicant:
STAGMO INVESTMENTS LLC
Description:
UNSTABLE DOOR FRAMES/ LEAK IN THE KITCHEN / OTHER ISSUES
Outstanding Inspections
Case Number: T15DV05149
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/05/2015 | NPO(PL)-PLUMBING SYSTEM & FX | VIDAL | Follow-up inspection | |
11/05/2015 | NPO - EGRESS | VIDAL | Follow-up inspection | |
11/05/2015 | NPO - SMOKE ALARMS | VIDAL | Follow-up inspection | |
11/05/2015 | NPO - OTHER | VIDAL | Follow-up inspection | |
11/05/2015 | NPO - INT. BUILDING MAINTENANC | VIDAL | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T15DV05149
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/17/2015 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | Met with the tenant and the tenant has given a list to the manager and nothing has been done at this time. Found where the exterior doors are not sealed or lacking locking devices, windows are hard to open or are stuck with some painted shut, the plumbing is leaking under the sink, the drawer fronts are missing in several areas, missing globes on several light fixtures, outlets and light fixtures are missing coverplates, lacking smoke detectors, lacking heat to the unit, holes in the drywall in several areas, vents lacking on ceiling for the cooler, stucco falling off on the exterior wall on the north side at the bottom areas, dead front lacking on the exterior electrical panel, water heater has wood touching the vent pipe on the rear of the unit, pressure relief line is lacking at T.P.R. valve, metal box is lacking outlet or a coverplate, lacking light bulbs in some fixtures, and will need to be checked once these have been completed. Will try and make contact with the management. RV. |
11/05/2015 | INSP - FOLLOW UP CODE ENFORCE | VIDAL | Approved | Went to the property to do the inspection and the tenant left the property. At that time found out that the property has new ownership and under new management. Don't have the phone number or the names for the new owners but the tenant will try and get the information due to the rent is due. RV. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T15DV05149
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date | Name |
10/06/2016 | VIOLATION CLOSED |