Case: T15DV04148
Case Details
Entered Date:
06/08/2015
Applicant:
CAA INVESTMENTS I LP
Description:
COMMUNICATION CALLED THAT T.P.D. ON SITE WITH CAR THRU BUILDING, ALARM F151570108
Outstanding Inspections
Case Number: T15DV04148
Case Status: COMPLIAN
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Outstanding Inspections - 8
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2015 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | VIDAL | Item closed | |
08/25/2015 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VIDAL | Item closed | |
08/25/2015 | NPO - EGRESS | VIDAL | Item closed | |
08/25/2015 | NPO - SMOKE ALARMS | VIDAL | Item closed | |
08/25/2015 | NPO - OTHER | VIDAL | Item closed | |
08/25/2015 | NPO - EXT. BUILDING MAINTENANC | VIDAL | Item closed | |
08/25/2015 | NPO - WORK WITHOUT PERMIT | VIDAL | Item closed | |
08/25/2015 | NPO - INT. BUILDING MAINTENANC | VIDAL | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T15DV04148
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/06/2015 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | Communcation called that T.P.D. on site with a car thru building. Arrived and the vehicle was in the building into a bedroom on the northeast side of the structure. The manager and the maintenance was on site and the maintenance was going to secured once he vehicle was removed. The wall has wood framing studs with stucco on the exterior and drywall on the interior. The studs were broken in half. The window was broken. The vehicle was wedged in the wall and needed to be removed after the framing and stucco was removed. T.P.D. did drive the vehicle out and parked on the property for the owner. Once the opening was secured did a posting of "Do Not Enter" on the plywood. The electrical meter was booted due to the damage and had one outlet in the wall that was damaged. The manager signed all the paper work and went over that the tenants need to notify the management that they are entering the unit. The locks were going to be changed. The upper unit is vacant at this time and advised to keep vacant until the wall has been replaced with the proper wood framing studs. A metal diagonal bracing was removed due to the damage. A Alum. window was removed to remove the vehicle that was already broken. The wall has termite damage on the wood framing studs. Will check in 30 days. RV. |
08/25/2015 | INSP - FOLLOW UP CODE ENFORCE | VIDAL | Approved | All issues have been addressed and the permit has been finaled on 8-7-15 and the unit is rented out. At this time the case will be closed. Violation Abated, Close Case. RV. |
Completed Activity Special Conditions
Case Description - CAR THROUGH RESIDENTIAL BUILDI
Case Number - T15DV04148
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date | Name |
06/15/2015 | CONTACTED IN PERSON |
06/15/2015 | NOTICE AND ORDER ISSUED |
06/15/2015 | NOTICE OF VIOLATION ISSUED |
09/17/2015 | VIOLATION CLOSED |