NO SMOKE DETECTORS / LOOSE WIRES HANGING / NO PARKING / LACK OF EGRESS (NAILED REAR DOOR SHUT)

Outstanding Inspections

Case Number: T15DV03404
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
07/20/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX PUMPHREY Item closed
07/20/2015 NPO - EGRESS PUMPHREY Item closed
07/20/2015 NPO - SMOKE ALARMS PUMPHREY Item closed
07/20/2015 NPO - INT. BUILDING MAINTENANC PUMPHREY Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV03404
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/18/2015 INSP - INITIAL CODE ENFORCMENT PUMPHREY Approved Inspection of rear unit at request of tenant; front room has outlet installed at an angle; unit lacks any smoke detectors; rear (west) bedroom window has an incorrectly installed evaporative cooler with the switch box and cords loose directly in the plenum; cooler also lacks cover on the interior; bedroom door exits into private corridor which has blocked access to driveway or open area; the corridor is filled with storage and debris; water heater for unit in this area has deteriorated insulation frayed around top of vent intake, ignition, and bottom area inhibiting normal use; junction boxes (one interior, one exterior) lack covers; multiple lights lack globes or covers.
07/20/2015 INSP - FOLLOW UP CODE ENFORCE PUMPHREY Approved Inspection conducted of unit; all violations have been abated; case will be closed.

Outstanding Case Activity Conditions

Date Name Approved
05/19/2015 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. T.C. Ch. 16, Sec. 16-12(d) COOLERS. Evaporative coolers, cooler stands, and any cooler mounting apparatus must be maintained in a safe condition. Cooler stands and any mounting apparatus must be structurally sound. Not Approved
05/19/2015 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. Not Approved
05/19/2015 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. Not Approved
05/19/2015 T.C. Ch. 16, Sec. 16-11(a)(2) Every dwelling unit or guest room shall have unobstructed access directly to the outside, or to a public corridor. Every door, stairway, passageway or other means of exit shall be of sufficient size, width and arrangement so as to provide safe and rapid egress in the event of fire. Every walking surface of any means of exit shall be maintained free of warping, rotting, or other damage or obstructions so as to provide safe and rapid egress in the event of fire. Not Approved
05/19/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T15DV03404
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
05/12/2015 CONTACTED BY PHONE
05/28/2015 CONTACTED IN PERSON
05/19/2015 CONTACTED BY MAILING
05/19/2015 NOTICE OF VIOLATION ISSUED
06/10/2015 RESEARCH