Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

04/28/2015

Applicant:

SYLVIA R EADDY-BALDWIN

Description:

No water, furnace, plumbing, No A/C

Case Violations

Case Number: T15DV03194
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date Code Statue
05/01/2015 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
05/01/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
05/01/2015 T.C. Ch. 16, Sec. 16-13(d) DUTY TO REMOVE WEEDS AND REFUSE FROM ABUTTING SIDEWALKS, STREETS AND ALLEYS UPON NOTICE. Upon receipt of notice served pursuant to section 16-45, the owner, lessee, tenant or occupant of any premises shall remove from the premises and the abutting portions of contiguous sidewalks, streets and alleys, all weeds, garbage, debris or other refuse which may endanger the health, safety or welfare of the persons in the vicinity of such premises. This duty extends to and includes any abutting sidewalk area and one-half (½) the width of abutting alleys, from the property line to the center line of the alley.

Outstanding Inspections

Case Number: T15DV03194
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
05/22/2015 NPO(PL)-PLUMBING SYSTEM & FX VINDIOLA Item closed
05/22/2015 NPO(HC)-COOLING VINDIOLA Item closed
05/22/2015 NPO(HC)-HEATING & VENTILATION VINDIOLA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV03194
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/29/2015 INSP - INITIAL CODE ENFORCMENT VINDIOLA Approved COMPLIANT: No water, furnace, plumbing, No A/C FOUND: 3 UNITS WITH WATER METERS TO EACH UNIT, 725 (OCCUPIED ) & 727 (UNOCCIPIED) WITH BLUE TAGS AND LOCKED AT CURBSTOP, LAST UNIT 729 WITH WATER SVS AND OCCUPIED. 725 RAN A WATER HOSE FROM ONE UNIT TO HIS MAIN HOUSE VALVE THUS PROVIDING WATER TO HIS UNIT (ILLEGALLY) ASKED HIM TO DISCONNECT IT AND IT WAS.. TUCSON WATER WAS CALLED AND WATER WAS SHUT DUE TO NON PAYMENT AND TAMPERING WITH METER.. SHOWED ME INTO UNIT(2) SHOWER BACK WALL NOT COMPLETE AND DOWNSPOUT NOT ATTACHED (3) LAUNDRY ROOM BOTH WATER VALVE TO WASHING MACHING LEAKING (4) ELECTRICAL FACEPLATE MISSING ON OUTLET BY WASHING MACHINE (5) TRASH/DEBRIS AT CURB MATTRESS AND WOOD. FURNACE WAS NOT CHECKED DUE TO SEASON 85 DEGREES TODAY.. STATES HAS NO A/C BUT A COOLER AND HAS NOT TRIED TO START IT. PROPERTY POSTED AND NOTICES ALL POSTED. WILL F/U
05/22/2015 INSP - FOLLOW UP CODE ENFORCE VINDIOLA Approved ARRIVED ON SITE TO FIND OUTSIDE STILL CLEAR AND CLEAN .. GATES LOCKED AT FRONT .. UNABLE TO GAIN ENTRY .. TENANT MOVED OUT .. COULD STILL SEE UNIT 727 E PASTIME FROM GATES .. APEARS TO BE VACANT .. WILL MOVE TO CLOSE OUT THIS CASE ..

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T15DV03194
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
05/04/2015 CONTACTED BY PHONE
05/28/2015 VIOLATION CLOSED
05/01/2015 RESEARCH

Documents

File Name Document Type  
T15DV03194.PDF DOCUMENTS VIEW
NOV_725 E PASTIME RD_T15DV03194.PDF DOCUMENTS VIEW