Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

03/17/2015

Applicant:

PRISM HOLDINGS

Description:

EXPOSED ELECTRICAL , HOLES IN WALLS

Case Violations

Case Number: T15DV02033
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
Violation Date Code Statue
03/17/2015 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
03/17/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
03/17/2015 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
03/17/2015 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.

Outstanding Inspections

Case Number: T15DV02033
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
08/04/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX HOLLANDER Item closed
08/04/2015 NPO - INT. BUILDING MAINTENANC HOLLANDER Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV02033
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
03/17/2015 INSP - INITIAL CODE ENFORCMENT HOLLANDER Approved Visited the site and took pictures with the tenant. I had called the manager and left a message, but no return call. This is not a high priorty call. There are no exposed electrical conductors. There is short runs of NM cable from the subpanel in the closet to the ceiling and a short run at the eves outside. There is one missing receptacle cover plate. There are two small holes in the walls. he ceiling in the living and bedroom shows water damage. The hallway smoke alarm is missing. The bedroom window screen is missing. The service disconnects are not labeled as to which unit they serve for first responder to be able to use. The subpanel fuses are not labeled. There are missing LB covers and unused openings in the equipment. The condition of the equipment is questionable.
08/04/2015 INSP - FOLLOW UP CODE ENFORCE HOLLANDER Approved Visited the site and all items have been taken care of and Abated Close Case.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T15DV02033
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
03/26/2015 CONTACTED BY PHONE
04/22/2015 CONTACTED IN PERSON
03/19/2015 CONTACTED BY MAILING
03/19/2015 NOTICE OF VIOLATION ISSUED
08/04/2015 VIOLATION CLOSED

Documents

File Name Document Type  
3177 E FORT LOWELL RD ST #03.PDF DOCUMENTS VIEW
DSCN4832.JPG IMAGES VIEW
DSCN4813.JPG IMAGES VIEW
DSCN4814.JPG IMAGES VIEW
DSCN4815.JPG IMAGES VIEW
DSCN4816.JPG IMAGES VIEW
DSCN4817.JPG IMAGES VIEW
DSCN4818.JPG IMAGES VIEW
DSCN4819.JPG IMAGES VIEW
DSCN4820.JPG IMAGES VIEW
DSCN4821.JPG IMAGES VIEW
DSCN4822.JPG IMAGES VIEW
DSCN4823.JPG IMAGES VIEW
DSCN4824.JPG IMAGES VIEW
DSCN4825.JPG IMAGES VIEW
DSCN4826.JPG IMAGES VIEW
DSCN4827.JPG IMAGES VIEW
DSCN4828.JPG IMAGES VIEW
DSCN4829.JPG IMAGES VIEW
DSCN4830.JPG IMAGES VIEW
DSCN4831.JPG IMAGES VIEW