Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

11/20/2014

Applicant:

JULIE SIERRA REVOC TR

Description:

NO HEATING

Case Violations

Case Number: T14DV09613
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
Violation Date Code Statue
12/09/2014 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T14DV09613
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
11/25/2014 INSP - INITIAL CODE ENFORCMENT SMITH Approved Found a couple of issues with the heaters, unit 3 heater is ok after check with SW Gas they were out to the unit 3 in Jan 2014 and it was ok the renter ask that the unit not be turned on she has a space heater but was told by her Doctor not to use it because she is handy capped.. Unit 5 heater was condemed by SW Gas but the onwer stated that she has a space heater. Will be meeting with the contractor to check the unit in question and any other unit that we can get into. There is issues with the cooler on the roof with the elecrtical hook ups to the breaker box some have them and some don't.
12/09/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX SMITH Item initialized
12/09/2014 NPO(HC)-HEATING & VENTILATION SMITH Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV09613
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
12/09/2014 INSP - FOLLOW UP CODE ENFORCE SMITH Approved Heaters at 308 W Irvington Rd have been repaired or replaced. Unit 4 still need to be done but no one is living in the unit.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T14DV09613
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
11/25/2014 CONTACTED IN PERSON
12/01/2014 MENTOR ASSISTANCE
03/10/2015 VIOLATION CLOSED