Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

10/27/2014

Applicant:

CARAVAN II LLC, MANAGER: JODY M TESSIER

Description:

TRAILER FIRE / ELECTRICAL DAMAGE

Outstanding Inspections

Case Number: T14DV08993
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
10/29/2014 NPO(EL)-MAIN/PANEL/SUB/DISCONT GOODMAN Item closed
10/29/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX GOODMAN Item closed
10/29/2014 NPO(DL)-DILAPIDATED STRUCTURE GOODMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV08993
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/26/2014 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: THE MOBILE HOME UNIT NUMBER 176 HAD A WASHER AND DRYER CONNECTED AT THE REAR EXTERIOR OF THE MOBILE. THE DRYER CAUGHT FIRE ALONG WITH THE WASHER.. THE DAMAGE TO THE MOBILE HOME WAS MINIMAL SOME HEAT DAMAGE TO THE SKIN A LITTLE DISCOLORATION BUT STILL IN TACT. THE SUPPORT PLYWOOD TO THE WINDOW MOUNTED AC UNIT DID BURN. THE EXTERIOR COVER TO THE 110V OUTLET WITH A DUPLEX RECEPTACLE DID MELT, THIS RECEPTACLE IS NOT GFCI RECEPTACLE. ADJACENT TO THE 110V OUTLET IS A 220V OUTLET ENCLOSURE WHICH HAS A 30 AMP RECEPTACLE. THE ENCLOSURE IS NOT RATED FOR OUT DOOR USE AND THE NON METALLIC SHEATHED CABLE FOR THE DRYER IS EXPOSED AND NOT PROTECTED. THE LIFE LINE TO THE UNIT WAS UN PLUGGED. THE PEDESTAL IS NOT MARKED NOR IS THE BREAKERS INSIDE THE DISCONNECT. THE INTERIOR PANEL TO THE MOBILE HOME IS LOCATED IN THE CLOSET, THERE ARE 6 BREAKERS ALL NOT MARKED AND THEY ALL ARE SINGLE POLE 30 AMP BREAKERS. THE UNIT WAS CONDEMNED UNFIT TO OCCUPY.
10/29/2014 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved VISITED SITE PER INSPECTO VALDEZ, MET WITH TONY FROM SOVEREIGN ELECTRIC. INSPECTED THE SUB PANEL AND ALL BREAKERS HAD BEEN CHANGED OUT ACCORDINGLY TO 15 OR 20 AMP BREAKERS. CIRCUIT FOR THE WASHER/ DRYER HAD BEEN REMOVED AND OUTLET CAPPED. TENANT WILL BE ALLOWED BACK IN . COMPLIANCE /CLOSE CASE.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T14DV08993
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
10/29/2014 CONTACTED BY PHONE
10/27/2014 NOTICE AND ORDER ISSUED
10/29/2014 VIOLATION CLOSED
10/27/2014 CALLBACK

Documents

File Name Document Type  
3333 N FLOWING WELLS RD 176.PDF DOCUMENTS VIEW
DSCN9880.JPG DOCUMENTS VIEW
DSCN9873.JPG DOCUMENTS VIEW
DSCN9874.JPG DOCUMENTS VIEW
DSCN9875.JPG DOCUMENTS VIEW
DSCN9876.JPG DOCUMENTS VIEW
DSCN9877.JPG DOCUMENTS VIEW
DSCN9878.JPG DOCUMENTS VIEW
DSCN9879.JPG DOCUMENTS VIEW