Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING
Address:

Entered Date:

10/24/2014

Applicant:

FMTV LLC

Description:

EMERGENCY CALL / APARTMENT FIRE

Outstanding Inspections

Case Number: T14DV08932
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
10/23/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX GOODMAN Item initialized
10/23/2014 NPO - EGRESS GOODMAN Item initialized
10/23/2014 NPO - WORK WITHOUT PERMIT GOODMAN Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV08932
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/24/2014 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved OWNER/ LANDLORD: EMIEL METZGER 668-0222 / UNIT #128 TENANT : WHITNEY WARRANDER 289-5562 VISITED SITE, MET WITH TFD INVESTIGATORS WHO INFORMED ME FIRE STARTED IN THE REAR BEDROOM OF UNIT #106 AND FIRE WAS CONFINED WITH IN THE BEDROOM AND CLOSET. ** MET WITH LANDLORD EMIEL METZGER WHO STATED THE TENANT HAD JUST MOVED IN, HAD ONLY OCCUPIED THE UNIT FOR 2 DAYS. EMIEL ASKED HE BE ALLOWED TO SECURE THE REAR WINDOW AND ASKED IF HE COULD CHANGE THE LOCK ON THE FRONT DOOR, I OK'ED BOTH. SPOKE WITH TENANT WHITNEY WHO INFORMED ME THAT SHE WOULD STAY WITH A FRIEND TONIGHT BUT THAT TFD HAD CONTACTED RED CROSS TO PUT HER UP AFTER. >TFD HAD CALLED TEP AND POWER WAS SHUT OF AT THE MAIN DISCONNECT > TFD CONTACTED S/W GAS. THERE WAS NO GAS TO THE UNITS AND LINE TEST CHECKED OUT OK >TFD HAD CONTACTED RED CROSS FOR TENANT PLACEMENT. >OWNER DID SECURE BEDROOM WINDOW AND CHANGED LOCKS ON THE FRONT DOOR. FIRE DAMAGE: NOTE ALL EXTERIOR WALLS AND UNIT DIVIDING WALLS ARE BLOCK WALLS. CEILNGS OF THE 1ST FLOOR AND 2ND STORY FLOORS ARE POURED CONCRETE. > REAR BEDROOM NORTH WALL IS A FURRED OUT WALL, FRAMING OF FURR OUT AND FRAMED CLOSET WALL WERE FIRE DAMAGED. DOORS AND WINDOWS FIRE DAMAGED. > ALL DRYWALL IN THE BEDROOM AND CLOSET WAS FIRE DAMAGED OR RECEIVED VERY HEAVY SMOKE DAMAGE. >ELECTRIC WIRING IN THE BEDROOM, SWITCHES AND OUTLETS, AND FIXTURES WERE ALL FIRE DAMAGED AND WIRING LEFT EXPOSED OR MELTED, AND OR HEAT DAMAGED. >THE LIVINGROOM, KITCHEN AND DINING AREA, HALL AND BATHROOM RECEIVED HEAVY SMOKE DAMAGE. > REAR BEDROOM BASICALLY GUTTED BY FIRE. EMERGENCY NOV ORDER TO VACATE WAS ISSUED TO THE OWNER, INDEMNIFICATION PAPERWORK ISSUED TO THE OWNER AND NOTICE OF VIOLATION / PERMITS REQUIRE ALSO WENT TO THE OWNER.
09/25/2015 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved FOLLOW UP FOUND ALL WORK COMPLETED UNDER PERMIT T15CMO4040, AND FINALED 9/17/2015

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T14DV08932
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
10/24/2014 CONTACTED IN PERSON
10/06/2016 VIOLATION CLOSED
10/24/2014 CALLBACK