Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

10/10/2014

Applicant:

M A P LLC

Description:

CIELING IS CAVING IN THERE IS A WATER LEAK. SEPTIC LINES ARE NOT HOOKED UP RIGHT . AIR CONDITIONING UNIT IS NOT WORKING ALONG WITH HEATING

Case Violations

Case Number: T14DV08496
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
Violation Date Code Statue
10/28/2014 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T14DV08496
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
10/28/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX GOODMAN Notice of violation
10/28/2014 NPO(PL)-PLUMBING SYSTEM & FX GOODMAN Notice of violation
10/28/2014 NPO(PL)-SEWAGE DISPOSAL (SYS) GOODMAN Notice of violation
10/28/2014 NPO(HC)-COOLING GOODMAN Notice of violation
10/28/2014 NPO(HC)-HEATING & VENTILATION GOODMAN Notice of violation
10/28/2014 NPO(DL)-DILAPIDATED STRUCTURE GOODMAN Notice of violation
10/29/2014 NPO - WORK WITHOUT PERMIT GOODMAN Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV08496
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/17/2014 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE MET WITH OCCUPANT JESSICA SHAEFFER, ASKED IF SHE OWNED THE TRAILER, SHE MENTIONED SHE HAD A LEASE TO OWN OPTION WITH THE TRAILER PARK. JESSICA PROVIDED THE PAPERWORK AND ALLOWED ME TO READ THE LEASE, I FOUND NO VERBAGE CONCERNING WHO IS RESPONSIBLE FOR ANY REPAIRS TO THE TRAILER. JESSICA MENTIONED THE MANAGER JOY DERRICK WAS LAST ON THE PROPERTY ON 10/09/2014. WALKED THE EXTERIOR OF THE TRAILER BEFORE ENTERING AND FOUND THE TRAILER HAD A ADDITION TO THE TRAILER, JESSICA MENTIONED SHE BOUGHT THE TRAILER AS IS. (HAS BEEN THERE SINCE MARCH) JESSICA MENTIONED SHE HAD SEVERAL ITEMS SHE FELT NEEDED TO BE ADDRESSED. WE STARTED IN THE N/W BEDROOM LOCATED IN THE ADDITION PART OF THE TRAILER. MY FINDINGS ARE AS FOLLOWS: > ROOM ADDITION (WORK WITHOUT PERMITS) > CEILING LEAK IN N/W BEDROOM HAS DAMAGED CEILING TILES EVIDENCED BY WATER SPOTS ON DROPPED CEILING TILE. >LEAK IN N/W BEDROOM HAS ALSO DAMAGED THE WALL PANELING EVIDENCED BY WATER ON THE FLOOR, AND WINDOW MAY BE LEAKING. PANELING BOWING AND CRACKING. > TWO WINDOWS IN THE "FAMILY ROOM PORTION OF THE ADDTION ALSO LEAKING, EVIDENCED BY WET FLOORING. TENANT HAS TRIED TO FOAM AND OR TAPE TO THE WINDOWS. >INCORRECT DOOR TYPE AND FRAME IN ADDITION AND DOOR NOT PROPERLY SEALED EVIDENCED BY DAYLIGHT ALL AROUND THE DOOR. > LEAK FOUND IN N/E BEDROOM NEAR THE WINDOW EVIDENCED BY WATER ON THE FLOOR. > PANELING ON THE WALL HAS BUCKLED DUE TO PANELING BEING TEXTURED AND THEN PAINTED. > BATHROOM TUB SURROUND HAS NOT BEEN PROPERLY INSTALLED EVIDENCED BY THE WALL BEING ABLE TO BE PUSHED IN AT THE BOTTOM OF THE SURROUND AND ALLOWING WATER TO LEAK INTO THE WALL DUE TO THE IMPROPER SEAL. > WHILE INSPECTING FLOOR DUCTS FOR LACK OF AIR I FOUND THE FLOOR HAD BEEN LIFTED APPROX 6-7 INCHES, FRONT DOOR IS NOW ONLY 6 FT IN HEIGHT INSTEAD OF 6FT 8 INCHES. >A/C UNIT/ DUCTWORK BLOWS PROPERLY FROM CERTAIN FLOOR GRILLES BUT NOT FROM ALL GRILLES TELLING ME IT MAY BE THE DUCT WORK IS NOT PROPERLY INSTALLED. > A/C UNIT HAS BEEN ADDED, CONNECTION OUTSIDE IS HAZARDOUS, EXPOSED TO THE ELEMENTS. >HOT WATER HEATER LACKS A ENCLOSER, HOT AND COLD WATER SHUT OFF, AND PRESSURE RELIEF VALVE.
09/25/2015 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved ALL ISSUES ABATED UNDER GENERAL REPAIR PERMIT T14CMO7697. SPOKE WITH MANAGER JOY DERRICK WHO STATED TENANT JESSICA SHAEFFER CALLED IN THE ISSUES WITH THE INTENTIONS OF BREAKING HER LEASE. MY FOLLOW UP DID FIND ALL ISSUES HAD BEEN ABATED. COMPLIANCE CLOSE CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T14DV08496
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
10/28/2014 CONTACTED BY MAILING
10/28/2014 NOTICE OF VIOLATION ISSUED
10/06/2016 VIOLATION CLOSED