Case Details

Status:

COMPLIAN

Type:

CAR THROUGH RESIDENTIAL BUILDI

Entered Date:

08/25/2014

Applicant:

TIGHE SHANNON M

Description:

EMERGENCY CALL / CAR INTO BUILDING

Outstanding Inspections

Case Number: T14DV06450
Case Status: COMPLIAN
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
08/24/2014 NPO(DL)-DILAPIDATED STRUCTURE GOODMAN Item initialized
08/24/2014 NPO - WORK WITHOUT PERMIT GOODMAN Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV06450
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/25/2014 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE PER TPD / CAR INTO BUILDING. UPON ARRIVAL I FIRST MET WITH TPD OFFICERS, FOUND A WHITE DODGE DURANGO HEADING WEST HAD ENTERED THE FRONT OF THE PROPERTY STRIKING THE FRONT PORCH COLLUM, WHERE THE PORCH MEETS THE CARPORT. LOOKED INSIDE THE CARPORT AREA, FOUND DRYWALL DAMAGE APPROX 10FT X 8FT AND 4-6 STUDS DAMAGED OR DISPLACED FROM THE CARPORT EXTERIOR EAST WALL. THE DAMAGED COLLUM ON THE FRONT POCH APPEARED TO BE A FALSE, FRAMED COLLUM AND PORCH BEAM POSSIBLY IS SUPPORTED IN THE CARPORT WALL. FROM THE CARPORT I FOUND A ELECTRICAL WIRE TORN IN HALF, CHECKED SERVICE PANEL BUT FOUND NO TRIPPED BREAKERS. I PLACED WIRE NUTS ON EACH END OF THE WIRING. STUDS ON THE COLLUM ALSO DAMAGED OR DISPLACED. NOV WAS ISSUED FOR ALL REPAIRS TO BE COMPLETED UNDER PERMIT, NOV SIGNED FOR BY THE OWNER
06/23/2015 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved MET WITH OWNER SHANNON TYGE WHO STATED THE WORK COMPLETED DID NOT REQUIRE A PERMIT PER THE CONTRACTOR WHO DID CHECK WITH DSD AND DUE TO THE STUCCO ONLY REQUIRING PATCHING, DRYWALL ONLY REQUIRING PATCHING AND STUDS DISPLACED FROM THE BOTTOM PLATE ONLY NEEDING TO BE RESECURED TO THE BOTTOM PLATE. ALL WORK WAS COMPLETED, PICTURES WERE TAKEN BY THE OWNER OF WORK COMPLETED. COMPLIANCE CLOSE CASE.

Completed Activity Special Conditions

Case Description - CAR THROUGH RESIDENTIAL BUILDI
Case Number - T14DV06450
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
08/29/2014 CONTACTED IN PERSON
08/29/2014 NOTICE OF VIOLATION ISSUED
12/08/2015 VIOLATION CLOSED