Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

08/19/2014

Applicant:

ARMSTRONG JOHN R & GUADALUPE K CP/RS

Description:

TFD DESCRIPTION ELECTRICAL HAZARDS

Outstanding Inspections

Case Number: T14DV06220
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
08/22/2014 NPO(EL)-MAIN/PANEL/SUB/DISCONT GOODMAN Item closed
08/22/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX GOODMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV06220
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/19/2014 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved RECEIVED CALL FROM TFD FOR ELECTRICAL HAZARDS AT A SINGLE FAMILY RESIDENCE. UPON MY ARRIVAL I FOUND THAT TFD HAD CLEARED THE SCENE. MET WITH OCCUPANTS DAVID AND CATHY ORTEGA WHO MENTIONED THEY HAD A BREAKER TRIP ON 8/17, RESET THE BREAKER. ON 8/18 THEY HEARD A VERY LOUD POP AND SMELLED BURNING AND SAW SMOKE COMING FROM THE SUB PANEL INSIDE. I CHECKED THE SUB PANEL AND EXCEPT FOR MIXED BREAKERS I FOUND NOTHING REALLY WRONG, NO BURNING OR BURN MARKS, PROPER WIRING ETC. I CHECKED THE MAIN SERVICE PANEL AND IT ALSO LOOKED LIKE IT WAS PROPERLY WIRED. I CALLED AND SPOKE WITH PROPERTY MANAGER QUAY, WHO MENTIONED ELECTRICIAN HAD ALREADY BEEN OUT AND TOLD OCCUPANTS THAT THEY WERE OVERLOADING A CIRUIT. I ASKED IF HE COULD GET A LICENSED ELECTRICIAN TO EVALUATE THE ELECTRICAL SYSTEM AND HE SAID HE COULD DO THAT BUT WOULD NEED TO CALL THEM THE NEXT MORNING. BECAUSE QUAY HAD A ELECTRICIAN OUT ALREADY AND BECAUSE HE WAS WILLING TO MEET ME THE FOLLOWING DAY I PUT OFF ISSUING A NOV UNTIL I MEET WITH QUAY. *** 8/19/2014 RECEIVED A CALL FROM QUAY WHO MENTIONED HE HAS A ELECTRICIAN LINED UP TO MEET HIM AT 2:00 PM COULD I MEET HIM THERE. ALL PARTIES AGREED TO MEET. I CHECKED PERMITS PLUS AND FOUND THAT THE SERVICE PANEL HAD BEEN UPGRADED TO A 200 AMP SERVICE IN 2004 PERMIT #T04EL02180 AND THAT WAS A CONCERN WHEN I SAW MAIN SERVICE PANEL. I DID SPEAK WITH RICK HOLLINGER WHO WILL ALSO MEET ON SITE.
08/22/2014 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved RECEIVED CALL FROM ANGEL VILLALBA WHO STATED HE DID CHECK LOADS ON ALL BREAKERS, STATED THAT THE SMOKE SMELL INSIDE CAME FROM A OLD MOTOR IN THE COOLER, CHANGED OUT THE MOTOR FOR A NEW ONE AND CHECKED THAT COOLER WAS NOW RUNNING PROERLY. BREAKERS WERE CHANGED OUT FOR PROPER BREAKERS. ** CALLED AND SPOKE TO RICK H TO DETERMINE IF A PERMIT WOULD BE REQUIRED FOR ANYTHING, RICK SAID NO. CALLED AND SPOKE TO OCCUPANTS WHO CONFIRMED THE WORK THAT WAS DONE. ISSUE ABATED. COMPLIANCE / CLOSE CASE.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T14DV06220
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
09/15/2014 VIOLATION CLOSED