Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-COMMERCL
Address:

Entered Date:

05/07/2014

Applicant:

JOSE A. & VIRGINIA S. FLORES JT/RS

Description:

Hazardous electrical on vacant land parcel supplied to Peddler.

Outstanding Inspections

Case Number: T14DV02904
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
06/09/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ No violation
06/09/2014 NPO - EXT. HAZ/ATTRACT NUISANC VALDEZ No violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV02904
Case Description: WORK WITHOUT PERMITS-COMMERCL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/07/2014 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved THERE ARE TWO RECEPTACLE OUTLETS MOUNTED ON A DILAPIDATED POST WITH MULTIPLE SUPPORTING PIECES OF WOOD OR STEEL. THE MAIN POST HAS MOVEMENT SO THERE HAS BEEN ROPE WRAPPED AROUND THE POST AND THE SUPPORTING MEMBERS SO HELP ELIMINATE THE MOVEMENT. THIS METHOD HAS FAILED. THE OUTLET WITH THE 110 V DUPLEX RECEPTACLE IS NOT PROPERLY MOUNTED AND LOOSE, THE BOX EXTENSION HAS SEPARATED FROM THE MAIN BOX IS NOW NOT WEATHER PROTECTED, THE RECEPTACLE IS NOT GFCI TYPE. THIS JUNCTION BOX ALSO HAS ROPE WRAPPED AROUND IT FOR SUPPORT. THE SECOND OUTLET HAS AND 30 AMP RECEPTACLE. THE RECEPTACLE IS LOOSE AND NOT PROPERLY SEATED OR PROTECTED. THIS JUNCTION BOX ALSO HAS ROPE WRAPPED AROUND IT FOR SUPPORT. THE EXTENSION CORDS BEING BY USED BY THE PEDDLER HAVE SPLICES AND DEFECTS. AN INDOOR POWER STRIP IS BEING USED FOR THE FREEZER CONNECTED UNDER THE MESQUITE TREE. THE 30 AMP CORD IS POWERING THE FREEZER UNIT ON THE TRUCK. THERE HAS BEEN AN INSTALLATION OF A PRIVATE METER AT THIS LOCATION. THIS EQUIPMENT HAS BEEN INSTALLED ON THE VACANT LOT. THE SOLE PURPOSE AND USE FOR THIS EQUIPMENT AT THIS TIME IS FOR THE PEDDLER'S EQUIPMENT. THE EQUIPMENT ON THE VACANT LOT HAS NO OVER CURRENT PROTECTION DEVICE. THIS EQUIPMENT IS BEING FEED BY AN UNDERGROUND FEEDER FROM THE ADJACENT BUILDING WHICH IS ON A DIFFERENT PARCEL. THIS EQUIPMENT WAS INSTALLED WITHOUT A PERMIT. THIS EQUIPMENT IS IN A HAZARDOUS STATE. THE INSTALLATION OF THIS EQUIPMENT IS NOT CODE COMPLIANT AND MUST BE REMOVED TO PREVENT FUTURE USE. ACTION TAKEN BY THE CITY OF TUCSON. I HAND DELIVERED THE NOTICE OF VIOLATION TO THE TENANT WITH INSTRUCTIONS TO GIVE TO THE OWNER; O DAYS TO UNPLUG ALL SPLICED AND DEFECTIVE EXTENSION CORDS. WITHIN 24 HOURS TO SHUT THE CIRCUIT BREAKERS OFF AND 10 DAYS TO REMOVE THE DILAPIDATED SYSTEM.
06/09/2014 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved PERMIT T14CM02705 IS FINAL BY LEERAY. CLOSE CASE

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-COMMERCL
Case Number - T14DV02904
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
05/08/2014 CONTACTED BY PHONE
05/08/2014 CONTACTED IN PERSON
06/09/2014 VIOLATION CLOSED

Documents

File Name Document Type  
4556 S 12TH AVE.PDF DOCUMENTS VIEW
P4180095.JPG DOCUMENTS VIEW
P4180087.JPG DOCUMENTS VIEW
P4180088.JPG DOCUMENTS VIEW
P4180089.JPG DOCUMENTS VIEW
P4180090.JPG DOCUMENTS VIEW
P4180091.JPG DOCUMENTS VIEW
P4180092.JPG DOCUMENTS VIEW
P4180093.JPG DOCUMENTS VIEW
P4180094.JPG DOCUMENTS VIEW