Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

03/31/2014

Applicant:

SPITZER FAMILY LIMITED PARTNERSHIP

Description:

FIRE IN LADIES RESTROOM

Outstanding Inspections

Case Number: T14DV02051
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
04/09/2014 NPO(EL)-MAIN/PANEL/SUB/DISCONT VIDAL Item closed
04/09/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX VIDAL Item closed
04/09/2014 NPO(HC)-HEATING & VENTILATION VIDAL Item closed
04/09/2014 NPO - INT. BUILDING MAINTENANC VIDAL Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV02051
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
03/31/2014 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Received call from Joseph that T.F.D. on site with a electrical fire in the ladies bathroom. Arrived and the fire was ready to leave and had a fire on the exhaust fan in the ladies bathroom. The fan had been removed and had wire nuts on the ends of the romex. The power was turned back on and all was working. Found other issues with the electrical panel on the exterior where lacking a protective cover over a opening where a breaker is not placed. The romex under the panel was not protected and was less than 8'. Had a j-box that was lacking the cover plate. Those issues were shown to the workers and they will address the issues in the storage room in the rear of the building. The light fixture in the ladies bathroom is lacking the lens and was pulled off during the fire. Will be placed back on the light fixture. The manager of the business has called an electrician and will be on site tomorrow to look and make the repairs needed to install the exhaust fan back into the opening. The business can remain opened and will check in 5 days. RV.
04/09/2014 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved The fan was removed from the ladies bathroom due to has another one that is working. The opening has been covered and all the other issues have been addressed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T14DV02051
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
04/15/2014 VIOLATION CLOSED
03/31/2014 CALLBACK

Documents

File Name Document Type  
DAMAGE REPORT T14DV02051.PDF DOCUMENTS VIEW