Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES
Address:

Entered Date:

01/24/2014

Applicant:

BAMHP LLC, ATTN: RONALD E & SUZANNE SALISBURY

Description:

Panel board for 18 units, old equipment, deteriorated conditions.

Outstanding Inspections

Case Number: T14DV00449
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
12/11/2014 NPO(EL)-MAIN/PANEL/SUB/DISCONT PUMPHREY Item closed
12/11/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX PUMPHREY Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV00449
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/21/2014 INSP - INITIAL CODE ENFORCMENT PUMPHREY Approved Junction boxes for approx. 18 units (aged meter & service disconnect housed in junction boxes); the equipment is dilapidated, rusted, aged, and due to its age lacks the deadfronts that would now be required under code. Wood supports deteriorated by weather and termite damage. Supervisors at location and agreed to further review the equipment at location with RH. Located south of unit A (site built). See inspection for 1/22/14.
12/11/2014 INSP - FOLLOW UP CODE ENFORCE PUMPHREY Approved Site review with owner, electrician, I.Stevens and myself; compliant; permit T14CM07610 finaled; grounding of boxes included.

Outstanding Case Activity Conditions

Date Name Approved
04/16/2014 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. Not Approved
04/16/2014 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. Not Approved
04/16/2014 T.C. Ch. 16, Sec. 16-14. Dilapidated structures; vacant and unsecured structures; buildings and structures constituting a nuisance. (a) Dilapidated structures. Buildings or structures that are so deteriorated, damaged, dilapidated, or in need of repair so as to present a threat to the health, safety and welfare of the community constitute a nuisance and shall be abated by repair, rehabilitation or demolition as provided in Article VI of this chapter. Not Approved
04/16/2014 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. Not Approved
04/16/2014 T.C. Ch. 16, Sec. 16-13(a) ACCUMULATION OF VEGETATION PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of the accumulation or untended growth of vegetation. The accumulation or untended growth of vegetation means the presence of plants on property that create a fire, safety or health hazard, or that attract vermin either on the property, on neighboring properties, or on both, and includes but is not limited to: (1) Any lawn grass that exceeds 6 inches in height; (2) All weeds that exceed 6 inches in height; (3) Dead trees and dead shrubs; (4) Dead palm fronds within ten fee of the ground, a structure, a fence or wall, or of any combustible other than the tree from which the fronds have grown; (5) Any tree, shrub, or other form of vegetation of any kind on the property or on the adjoining right-of-way, street, or alley that extends over or under the sidewalk space or roadway in a manner that may interfere with the reasonable use of the street, sidewalk, or alley for pedestrian or vehicular traffic of any kind or that may obstruct the view or light distribution of traffic-control devices or luminaries; (6) Vegetation must be trimmed and maintained to provide an unobstructed pedestrian path a minimum 48 inches in width and 80 inches in height from grade. Not Approved

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T14DV00449
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
01/24/2014 CONTACTED BY PHONE
07/07/2014 CONTACTED IN PERSON
10/30/2014 CONTACTED BY EMAIL
08/07/2014 MENTOR ASSISTANCE
01/24/2014 NOTICE OF VIOLATION ISSUED
01/08/2015 VIOLATION CLOSED
01/24/2014 REFERENCE

Documents

File Name Document Type  
1455 W PRINCE - MULTI PANEL.PDF DOCUMENTS VIEW
DSCN2332.JPG IMAGES VIEW
DSCN2337.JPG IMAGES VIEW
DSCN2344.JPG IMAGES VIEW
DSCN2343.JPG IMAGES VIEW