Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

01/06/2014

Applicant:

ROBERT M. & CHARLOTTE LONDER TR

Description:

No heat at the 2461 N Alvernon location. Permits plus only allowed to enter by parcel address.

Case Violations

Case Number: T14DV00042
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
Violation Date Code Statue
01/21/2014 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
01/21/2014 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
01/21/2014 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation.
01/21/2014 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
01/21/2014 T.C. Ch. 16, Sec. 16-11(a)(2) Every dwelling unit or guest room shall have unobstructed access directly to the outside, or to a public corridor. Every door, stairway, passageway or other means of exit shall be of sufficient size, width and arrangement so as to provide safe and rapid egress in the event of fire. Every walking surface of any means of exit shall be maintained free of warping, rotting, or other damage or obstructions so as to provide safe and rapid egress in the event of fire.
01/21/2014 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
01/21/2014 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.

Outstanding Inspections

Case Number: T14DV00042
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 8
End Date Description Inspector Results Comments
09/05/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX BIGMAN Item closed
09/05/2014 NPO(PL)-WATER HEATERS BIGMAN Item closed
09/05/2014 NPO(HC)-HEATING & VENTILATION BIGMAN Item closed
09/05/2014 NPO - EGRESS BIGMAN Item closed
09/05/2014 NPO - SMOKE ALARMS BIGMAN Item closed
09/05/2014 NPO - REFUSE/TRASH/DEBRIS BIGMAN Item closed
09/05/2014 NPO - EXT. BUILDING MAINTENANC BIGMAN Item closed
09/05/2014 NPO - INT. BUILDING MAINTENANC BIGMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV00042
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/07/2013 INSP - INITIAL CODE ENFORCMENT BIGMAN Approved WENT TO DOOR KNOCKED NO ANSWER, LEFT MESSAGE ON THE DOOR FOR OWNER TO CONTACT ME AND SCHEDULE A TIME TO MEET.
09/05/2014 INSP - FOLLOW UP CODE ENFORCE BIGMAN Approved 8/27/14 OWNER'S DAUGHTER OBTAINED A PERMIT FOR THE ELECTRIC HEATER AND SCHEDULED AN INSPECTION PASSED. CASE ABATED. SUBMITTED CIVIL MOTION TO CTY ATTY. CLOSE OUT CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T14DV00042
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
01/30/2014 CONTACTED BY PHONE
01/29/2014 CONTACTED BY MAILING
06/27/2014 CERTIFIED RECEIPT CARD
01/29/2014 NOTICE OF VIOLATION ISSUED
06/23/2014 CITATION ISSUED
09/12/2014 VIOLATION CLOSED
06/23/2014 COURT HEARING INFO

Documents

File Name Document Type  
T14DV00042.PDF DOCUMENTS VIEW
20140623163133524.PDF DOCUMENTS VIEW