Case: T13DV09192
Case Details
Entered Date:
12/10/2013
Applicant:
PIMA COUNTY REAL PROPERTY SERVICES
Description:
House Fire Main House where the fire was started -- unit 1.
Case Violations
Case Number: T13DV09192
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 1
| Violation Date | Code Statue |
|---|---|
| 01/03/2014 | T.C. Ch. 6, IBC adopted. IBC 110.1 USE AND OCCUPANCY. No building or structure shall be used or occupied, and no change in the existing occupancy classification of a building or structure or portion thereof shall be made until the building official has issued a certificate of occupancy therefore as provided herein. |
Outstanding Inspections
Case Number: T13DV09192
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 11
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | JREED | Item initialized | |
| 12/10/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JREED | Item initialized | |
| 12/10/2013 | NPO(PL)-PLUMBING SYSTEM & FX | JREED | Item initialized | |
| 12/10/2013 | NPO(PL)-GAS SUPPLY/CONNECT | JREED | Item initialized | |
| 12/10/2013 | NPO(HC)-COOLING | JREED | Item initialized | |
| 12/10/2013 | NPO(HC)-NO VENTILATION | JREED | Item initialized | |
| 12/10/2013 | NPO(HC)-HEATING & VENTILATION | JREED | Item initialized | |
| 12/10/2013 | NPO(DL)-DILAPIDATED STRUCTURE | JREED | Item initialized | |
| 12/10/2013 | NPO - SMOKE ALARMS | JREED | Item initialized | |
| 12/10/2013 | NPO - EXT. HAZ/ATTRACT NUISANC | JREED | Item initialized | |
| 12/10/2013 | NPO - INT. BUILDING MAINTENANC | VIDAL | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV09192
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2013 | INSP - INITIAL CODE ENFORCMENT | RVIDAL | Approved | Received a call from Richard Diaz the T.F.D. on site with a house fire. Arrived and the units were doing the overhaul and monitoring the interior for CO. The fire was in the main house and started in the southwest bedroom and the fire went into the hallway. The other bedrooms had the doors closed and the doors were damaged. Has heavy smoke damage through out the house. 3-vent holes were cut on the roof. Holes were made in the plaster ceilings where checking for fire in the attic. The electrical was removed at the panel for the main house to try and keep the other unit occupied. The wiring was pulled from the breakers due to not able to do a lock out on the breakers. The panel feeds both structures. The gas is tied together and found where a union can be removed and install a cap to block the main house for gas and leaving the gas on to the other unit. Pima County owns the structures and will be securing the property. The Red Cross has been called to the site for placement and Pima County is working for another location for the tenants to stay. The Reps. signed the paper work and took pictures and left the site. Will check in 30 days. RV. |
| 03/17/2014 | INSP - FOLLOW UP CODE ENFORCE | VIDAL | Approved | The property is vacant and secured. Has fence panels on the front of the property blocking access into the property at the driveways. The property has a permit for the building to be demo'ed and was issued today, T14BUOO273. Pima County owns the property and will be working on the river banks once the building is removed. Will check in 90 days. RV. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T13DV09192
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 04/02/2014 | NOTICE AND ORDER ISSUED |
| 04/02/2014 | NOTICE OF VIOLATION ISSUED |
| 04/15/2014 | VIOLATION CLOSED |
| 01/03/2014 | 8-5 CITY COMM EMERGENCY |