Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T13DV09167
Case Details
Entered Date:
12/09/2013
Applicant:
MAN TRAN & HAO THI NGUYEN JT/RS
Description:
housing issues
Case Violations
Case Number: T13DV09167
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
| Violation Date | Code Statue |
|---|---|
| 12/16/2013 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
| 12/16/2013 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 12/16/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 12/16/2013 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
Outstanding Inspections
Case Number: T13DV09167
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | JHURD | Notice of violation | |
| 12/17/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JHURD | Notice of violation | |
| 12/17/2013 | NPO - SMOKE ALARMS | JHURD | Notice of violation | |
| 12/17/2013 | NPO - EXT. BUILDING MAINTENANC | JHURD | Notice of violation | |
| 12/17/2013 | NPO - INT. BUILDING MAINTENANC | JHURD | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV09167
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/08/2013 | INSP - INITIAL CODE ENFORCMENT | ESTEVENS | Approved | At site, spoke to tenant . I found disconnected wires at the furnance and circuit board. Breaker is in off postion. Smoke detector is missing in the hallway. Bedroom closet light is missing on/off pull chain. Outlets in the kitchen won't hold a plug, not GFCI. Outlets in the living room, bedroom and bathroom won't hold a plug. Thermostat missing. Door knob will not latch when closed and weather strip around the door is missing. Pass information on to area inspector. |
| 12/16/2013 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | N/O/V ISSUED. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T13DV09167
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 12/16/2013 | CONTACTED BY PHONE |
| 12/09/2013 | CONTACTED IN PERSON |
| 12/17/2013 | CONTACTED BY MAILING |
| 12/17/2013 | NOTICE OF VIOLATION ISSUED |
| 04/19/2017 | VIOLATION CLOSED |
| 12/09/2013 | CALLBACK |