Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

12/05/2013

Applicant:

JOSE & JOSEFA HOLGUIN REVOC TR

Description:

ELECTRICAL VIOLATIONS

Case Violations

Case Number: T13DV09108
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 5
Violation Date Code Statue
12/05/2013 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition.
12/05/2013 T.C. Ch. 16, Sec. 16-14. Dilapidated structures; vacant and unsecured structures; buildings and structures constituting a nuisance. (a) Dilapidated structures. Buildings or structures that are so deteriorated, damaged, dilapidated, or in need of repair so as to present a threat to the health, safety and welfare of the community constitute a nuisance and shall be abated by repair, rehabilitation or demolition as provided in Article VI of this chapter.
12/05/2013 T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (1) The building or structure lacks safe and adequate means of exit in case of fire or panic.
12/05/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
12/09/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (5) When a structure is equipped with a gas supply system, it must be installed and maintained in a safe, hazard-free condition.

Outstanding Inspections

Case Number: T13DV09108
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
12/05/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT JVALDEZ Item initialized
12/05/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX JVALDEZ Item initialized
12/05/2013 NPO(PL)-GAS SUPPLY/CONNECT JVALDEZ Item initialized
12/05/2013 NPO(DL)-DILAPIDATED STRUCTURE JVALDEZ Item initialized
12/05/2013 NPO - REFUSE/TRASH/DEBRIS JVALDEZ Item initialized
12/05/2013 NPO - VACANT AND NEGLECTED JVALDEZ Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV09108
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/25/2013 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved MOBILE HOME PARK VIOLATIONS THERE IS A 400 AMP MASTER METERED SYSTEM WITH TWO 200 AMP SAFETY SWITCHES ADJACENT TO THE METER LOCATION. THERE IS ALSO A IS PANEL BOARD AND AN ABANDON 4 GANG JUNCTION BOX IN THE SAME LOCATION. 1. NO LABELING ON THE SAFETY SWITCHES 2. THE 4 GANG J-BOX IS NOT RATED FOR OUTDOOR 3. NO LABELING ON THE PANEL BOARD 4. SAFETY SWITCHES ARE NOT PROPERLY MOUNTED TO THE BACKER BOARD UNIT 1 1.PEDESTAL OK 2.GAS LINE NOT PROPERLY SECURED, EXCESSIVE MOVEMENT ON PIPING UNDER THE MOBILE HOME. 3.PROPERTY; CARPET ON THE GROUND AND TRASH & DEBRIS UNIT 2 1.PEDESTAL OK 2.GAS LINE NOT PROPERLY SECURED, EXCESSIVE MOVEMENT ON PIPING UNDER THE MOBILE HOME. 3.PROPERTY; CARPET ON THE GROUND UNIT 3 1.PEDESTAL OK 2.RV LIFE LINE HAS SPICES 3.CORD CAP HAS SINGLE GANG INTERIOR JUNCTION BOX TO THE RV ADAPTER / LIFE LINE. 4.PROPERTY; TORN CARPET ON THE GROUND, TORN SOFA, LITTER. UNIT 4 1.PEDESTAL OK 2.CORD CAP IS DAMAGED ( MUST BE REPLACED ) 3.GAS LINE NOT PROPERLY SECURED, EXCESSIVE MOVEMENT ON PIPING UNDER THE MOBILE HOME. 4.PROPERTY; CARPET ON THE GROUND, TRASH AND DEBRIS. 5.EXPOSED PVC WATER SUPPLY LINE UNIT 5 1.PEDESTAL HAS CORD TYPE LIFE LINE HARD WIRED 2.THE MAIN BREAKER IS A 30 AMP SINGLE POLE TYPE NO T HANDLE 3.PROPERTY; ANIMAL WASTE UNIT 6 1.THE MAIN BREAKER IS A 30 AMP SINGLE POLE TYPE NO T HANDLE 2.PROPERTY; ANIMAL WASTE 3.WATER LEAKS AT THE SUPPLY LINE. UNIT 7 1. PEDESTAL OK. UNIT 8 1.PEDESTAL HAS CORD TYPE LIFE LINE HARD WIRED 2.DEAD FRONT UNSECURED 3.USED OPENING NEXT TO SINGLE POLE 30 AMP BREAKER 4.GAS LINE NOT PROPERLY SECURED, EXCESSIVE MOVEMENT ON PIPING UNDER THE MOBILE HOME. UNIT 9 1.PEDESTAL OK 2.PROPERTY; TRASH AND DEBRIS UNIT 10 1.DEAD FRONT MISSING 2.PVC CONDUIT NOT PROPERLY INSTALLED WITH WATER CONNECTOR FITTING. 3.PROPERTY HAS TRASH AND DEBRIS 4.THIS UNIT IS VACANT WITH BROKEN WINDOWS, LOOK ABANDON. UNIT 11 1.PVC CONDUIT NOT PROPERLY INSTALLED 2.OVER CURRENT PROTECTION IS 60 AMPS 3.UNUSED OPENING, MISSING RECEPTACLE 4.GAS LINE NOT PROPERLY SECURED, EXCESSIVE MOVEMENT ON PIPING UNDER THE MOBILE HOME. 5.THIS UNIT IS VACANT ABANDON AND UNSECURED WITH A DILAPIDATED ATTACHED PORCH. UNIT 12 1.MAIN BREAKER NOT PROPERLY SEATED 2.GAS LINE NOT PROPERLY SECURED, EXCESSIVE MOVEMENT ON PIPING UNDER THE MOBILE HOME. UNIT 13 1.PEDESTAL HAS CORD TYPE LIFE LINE HARD WIRED 2.GAS LINE NOT PROPERLY SECURED, EXCESSIVE MOVEMENT ON PIPING UNDER THE MOBILE HOME. UNIT 14 1.THERE IS ONE UNUSED OPENING AT THE MAIN BREAKER COVER LOCATED WITHIN THE PEDESTAL. THE UNIT HAS ONE SINGLE POLE 30 AMP BREAKER. 2.GAS LINE NOT PROPERLY SECURED, EXCESSIVE MOVEMENT ON PIPING UNDER THE MOBILE HOME UNIT 15 1.PEDESTAL HAS CORD TYPE LIFE LINE HARD WIRED 2.DEAD FRONT IS NOT SECURED 3.THE OVER CURRENT PROTECTION MAIN BREAKER IS 100 AMPS, THE LIFE LINE IS 50 AMPS. 4.GAS LINE NOT PROPERLY SECURED, EXCESSIVE MOVEMENT ON PIPING UNDER THE MOBILE HOME UNIT 16 1.THERE IS ONE UNUSED OPENING AT THE MAIN BREAKER COVER LOCATED WITHIN THE PEDESTAL. THE UNIT HAS ONE SINGLE POLE 30 AMP BREAKER. UNIT 17 1.METER AT PEDESTAL IS BLANKED OFF UNIT 18 1.PEDESTAL HAS CONDUIT WHICH RUNS UNDER GROUND AND RISES UP ADJACENT TO THE MOBILE HOME TO A RADIATOR HOSE WHICH IS ACTING AS A CONNECTOR TO A JUNCTION BOX. 2.THE PEDESTAL BREAKERS NOT MARKED. THERE IS A 200 AMP AND A 50 AMP. UNIT 19 1.METER AT PEDESTAL IS BLANKED OFF UNIT 20 1.OK UNIT 21 1.THIS IS A SMALL BLOCK BUILDING WITH A SMALL MOBILE HOME ATTACHED. THE ARIEL'S SHOW THIS CONFIGURATION SINCE 1998. 2.GAS WATER HEATER HAS DRAIN VALVE THAT LEAKS 3.GAS WATER HEATER HAS VENT PIPE NOT PROPERLY ATTACHED 4.GAS WATER HEATER COMPARTMENT HAS MISSING DOOR 5.EXTERIOR JUNCTION BOX HAS MISSING COVER PLATE 6.SMALL ATTACHED AWNING IS DILAPIDATED LAUNDRY ROOM / BUILDING 1.MAIN DISCONNECT HAS NO LABELING. 2.UNSECURED DEAD FRONT 3.UNUSED OPENING AT BOTTOM OF DISCONNECT 4.30 AMP CIRCUIT BREAKER HAS 12 GAUGE WIRE 5.THE BUILDING HAS DEEP CRACKS IN THE MORTAR JOINTS 6.ALL OF THE WOOD HEADERS ALL SEVERELY DETERIORATED 7.TWO DAMAGED WINDOW OPENINGS
12/06/2013 INSP - FOLLOW UP CODE ENFORCE JVALDEZ Approved MEETING ONSITE WITH OWNER; SEE PERSON NOTES IN CONDITIONS.

Outstanding Case Activity Conditions

Date Name Approved
12/10/2013 2012 INTERNATIONAL RESIDENTIAL CODE CHAPTER 26 - GENERAL PLUMBING REQUIREMENTS SECTION P2603 STRUCTURAL AND PIPING PROTECTION P2603.5 FREEZING. IN LOCALITIES HAVING A WINTER DESIGN TEMPERATURE OF 32°F (0°C) OR LOWER AS SHOWN IN TABLE R301.2(1) OF THIS CODE, A WATER, SOIL OR WASTE PIPE SHALL NOT BE INSTALLED OUTSIDE OF A BUILDING, IN EXTERIOR WALLS, IN ATTICS OR CRAWL SPACES, OR IN ANY OTHER PLACE SUBJECTED TO FREEZING TEMPERATURE UNLESS ADEQUATE PROVISION IS MADE TO PROTECT IT FROM FREEZING BY INSULATION OR HEAT OR BOTH. WATER SERVICE PIPE SHALL BE INSTALLED NOT LESS THAN 12 INCHES (305 MM) DEEP AND NOT LESS THAN 6 INCHES (152 MM) BELOW THE FROST LINE. Not Approved

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T13DV09108
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
12/05/2013 CONTACTED BY PHONE
12/05/2013 CONTACTED IN PERSON
12/10/2013 CONTACTED BY MAILING
12/10/2013 NOTICE OF VIOLATION ISSUED
04/28/2014 VIOLATION CLOSED