Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

11/26/2013

Applicant:

334 VALENCIA TUCSON LLC

Description:

RESIDENTILA FIRE

Case Violations

Case Number: T13DV08915
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Violations: 1
Violation Date Code Statue
11/26/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T13DV08915
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
11/25/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT WNAVARRO Follow-up inspection
11/25/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX WNAVARRO Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV08915
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/23/2013 INSP - INITIAL CODE ENFORCMENT WNAVARRO Approved Visited site, met tenants on site, inspected, found as follows: electrical buse bar at termination for supply feed was loose and aching, dicussed power, tenant stated to me that maintainance had came by looked at it and stated that they could stay in unit,discussed options with the managemet and stated that they had a place to put them up but later found that the unit has no heat, no hot water and no cooking, I then explained the status of tenants being placed and that they had no authority to place them, I then called supervision and upon discusson would have them place for two days, arragements were made for the placement of the family, I then condemned unit and left power off, upon further inspection found that the main service dissconnect were in deteriorrated state and would require an upgrade for the service panel, an electrical contractor was contacted and I explained to him the requirements in securing permits, repair or replace sub panel and all inspections made prior to allowing tenants back into unit, took pictures and posted condemnation on door, asked the tenants if they had any place to stay for a couple of days and they did not. Also explained to mangement that if they could not put the tenants up that the City would have to establish a place, stated that they understood and that they would reimburse the City. They were put in a hotel for two days per supervision.
11/25/2013 INSP - FOLLOW UP CODE ENFORCE WNAVARRO Approved Tenat called and stated that they were not complete with the unit yet, called electrical contractor and he stated that he would be complete with the unit by late day the 11/25/2013, I then called tenat back and explained to them that they would be able to be back in ther unit by end of day, reseached and found permit had been secured

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T13DV08915
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
02/18/2014 CONTACTED BY PHONE
02/10/2014 CONTACTED BY MAILING
02/19/2014 CERTIFIED RECEIPT CARD
06/05/2014 RED CROSS / PRIMAVERA
02/10/2014 NOTICE OF VIOLATION ISSUED
03/19/2014 VIOLATION CLOSED
02/05/2014 RESEARCH