Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T13DV08915
Case Details
Entered Date:
11/26/2013
Applicant:
334 VALENCIA TUCSON LLC
Description:
RESIDENTILA FIRE
Case Violations
Case Number: T13DV08915
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Violations: 1
Violation Date | Code Statue |
---|---|
11/26/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T13DV08915
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/25/2013 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | WNAVARRO | Follow-up inspection | |
11/25/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | WNAVARRO | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV08915
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/23/2013 | INSP - INITIAL CODE ENFORCMENT | WNAVARRO | Approved | Visited site, met tenants on site, inspected, found as follows: electrical buse bar at termination for supply feed was loose and aching, dicussed power, tenant stated to me that maintainance had came by looked at it and stated that they could stay in unit,discussed options with the managemet and stated that they had a place to put them up but later found that the unit has no heat, no hot water and no cooking, I then explained the status of tenants being placed and that they had no authority to place them, I then called supervision and upon discusson would have them place for two days, arragements were made for the placement of the family, I then condemned unit and left power off, upon further inspection found that the main service dissconnect were in deteriorrated state and would require an upgrade for the service panel, an electrical contractor was contacted and I explained to him the requirements in securing permits, repair or replace sub panel and all inspections made prior to allowing tenants back into unit, took pictures and posted condemnation on door, asked the tenants if they had any place to stay for a couple of days and they did not. Also explained to mangement that if they could not put the tenants up that the City would have to establish a place, stated that they understood and that they would reimburse the City. They were put in a hotel for two days per supervision. |
11/25/2013 | INSP - FOLLOW UP CODE ENFORCE | WNAVARRO | Approved | Tenat called and stated that they were not complete with the unit yet, called electrical contractor and he stated that he would be complete with the unit by late day the 11/25/2013, I then called tenat back and explained to them that they would be able to be back in ther unit by end of day, reseached and found permit had been secured |
Completed Activity Special Conditions
Case Description - RESIDENTIAL FIRE
Case Number - T13DV08915
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date | Name |
02/18/2014 | CONTACTED BY PHONE |
02/10/2014 | CONTACTED BY MAILING |
02/19/2014 | CERTIFIED RECEIPT CARD |
06/05/2014 | RED CROSS / PRIMAVERA |
02/10/2014 | NOTICE OF VIOLATION ISSUED |
03/19/2014 | VIOLATION CLOSED |
02/05/2014 | RESEARCH |