Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

11/20/2013

Applicant:

SEONG PARK

Description:

STAIRS/RAILS- BROKEN TO THE 2ND FLOOR/KITCHEN SINK CLOGGED ON ONESIDE FOR 3 MOS/ TILE FLOOR BROKEN/ OVEN DRAWER BROKEN/WATER HEATER IN KITCHEN.

Case Violations

Case Number: T13DV08713
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
12/11/2013 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.
12/11/2013 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element.
12/11/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
12/11/2013 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability.
12/11/2013 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.

Outstanding Inspections

Case Number: T13DV08713
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
12/11/2013 NPO(PL)-PLUMBING SYSTEM & FX LPUMPHRE Notice of violation
12/11/2013 NPO(HC)-HEATING & VENTILATION LPUMPHRE Notice of violation
12/11/2013 NPO(DL)-DILAPIDATED STRUCTURE LPUMPHRE Notice of violation
12/11/2013 NPO - SMOKE ALARMS LPUMPHRE Notice of violation
12/11/2013 NPO - EXT. BUILDING MAINTENANC LPUMPHRE Notice of violation
12/11/2013 NPO - REGISTER RENTAL PROPERTY LPUMPHRE Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV08713
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/05/2013 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved 4 unit, 2 story multi unit complex. Site inspection results: Stairs & rails: railings are loose in places, missing bolts and not secured appropriately; steps are wood, weather dilapidated requiring weatherproofing and/or replacement in places; 2 steps are completely loose and cracked. Large support beam for second floor patio/walkway (transversing east/west near north side of stairs) is extremely dilapidated from termite damage and requires replacement. Second floor walkway is wood base with concrete overlayment and is cracked in several areas, with a completely broken section under north top railing which is also supported by termite damaged beam (damage is likely related). Support columns have deteriorated stucco at base, allowing moisture to penetrate base. Unit inspection #615: kitchen sink left side does not drain properly; vent in living room is missing cover; smoke alarm is not operable. Other: JMV in front parking area, no cover. All four units are rentals. Photos in Sire.
03/03/2014 INSP - FOLLOW UP CODE ENFORCE PUMPHREY Approved Compliant: Inspected interior of unit; vent cover has been replaced, smoke detector(s) are operating, and the sink is draining properly. The support beam and broken concrete on walkway were replaced and repaired under finaled permit T14CM01086. Stairs have been weatherproofed. Vehicle ok.

Outstanding Case Activity Conditions

Date Name Approved
12/11/2013 T.C. Ch. 16, Sec. 16-15. JUNKED OR INOPERABLE VEHICLES. (a) Prohibited storage (1) No person owning or having custody of any junked or inoperable vehicle may store such vehicle on private property, or on any sidewalks, streets or alleys, within the city, except as otherwise permitted under this section; (2) No person owning, occupying or in control of any private property within the city may store any junked or inoperable vehicle on the owned or occupied property, or on any abutting sidewalks, streets or alleys, except as otherwise permitted under this section; (b) Permitted storage This section shall not apply to any junked or inoperable vehicle stored on private property if the vehicle: (1) Is on the premises of a business enterprise operated in a lawful place and manner and licensed by the City under chapter 19 of the Tucson Code, and the storage of the vehicle is necessary to the operation of the business enterprise; or; (2) Is lawfully enclosed within: a. An enclosed garage or other permanent building lawfully constructed of opaque materials without openings, holes or gaps other than doors and windows; b. A carport, and an opaque car cover designed for that purpose (and not including tarps, bed sheets, plastic sheeting, or similar materials) completely covers the body of the vehicle; or c. Any fence, wall or barrier, not less than 5 feet in height, constructed of opaque materials without openings, holes or gaps other than gates or doors, completely enclosing the vehicle and screening it from view from any adjacent properties, and equipped with self-latching gates or doors. Such fence, wall or barrier must comply with section 16-12(e). (c) Persons responsible: Whenever the city finds that any junked or inoperable vehicle is stored on private property or on any abutting sidewalks, streets or alleys in violation of this section, the persons responsible for the violation include the recorded owner, occupant or person in control of the private property, as well as the registered owner or custodian of the vehicle. Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T13DV08713
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
11/26/2013 CONTACTED BY PHONE
01/06/2014 CONTACTED BY EMAIL
12/11/2013 NOTICE OF VIOLATION ISSUED
03/03/2014 VIOLATION CLOSED