Case Details

Status:

REFERRED

Type:

MULTIPLE TYPES

Entered Date:

07/18/2013

Applicant:

JOSE GRIJALVA & MARIA GARCIA-GRIJALVA

Description:

UNIT # 5: Exterior Inspection

Case Violations

Case Number: T13DV05172
Case Status: REFERRED
Case Description: MULTIPLE TYPES
Total Violations: 4
Violation Date Code Statue
07/18/2013 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
07/18/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
07/18/2013 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
07/26/2013 T.C. Ch. 6, IRC adopted. R311.3 LANDINGS AT EXTERIOR DOORS There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ΒΌ unit vertical in 12 units horizontal (2 percent).

Outstanding Inspections

Case Number: T13DV05172
Case Status: REFERRED
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
10/08/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT LPUMPHRE Follow-up inspection
10/08/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX LPUMPHRE Item closed
10/08/2013 NPO(PL)-PLUMBING SYSTEM & FX LPUMPHRE Item closed
10/08/2013 NPO(PL)-GAS SUPPLY/CONNECT LPUMPHRE Item closed
10/08/2013 NPO(PL)-SEWAGE DISPOSAL (SYS) LPUMPHRE Item closed
10/08/2013 NPO - EXT. BUILDING MAINTENANC LPUMPHRE Item closed

Completed Inspections

Case Status: REFERRED
Case Number: T13DV05172
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/28/2013 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved No handrail on steps; 2 doors lacking steps; elec circuits coming out of exterior light fixture to front porch has exposed spliced conducters and was added without permit; water service connector is not approved type or material (rubber hose); evap cooler stand is not structurally sound; cooler is connected to electrical system via wiring that was not installed to code, including use of extension cord, and has splices with exposed conductors; lifeline to main electrical panel is missing sheathing at end, requires replacement; gas service line has not shut-off valve; window boarded on door; sewer line lacking cleanout and is not sealed properly.
10/08/2013 INSP - FOLLOW UP CODE ENFORCE LPUMPHRE Approved Partial compliance; can't access lifeline, requires repair/replacement.

Outstanding Case Activity Conditions

Date Name Approved
07/26/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. Not Approved

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T13DV05172
Case Status: REFERRED
Total Completed Case Activity Conditions: 3
Date Name
09/10/2013 CONTACTED BY PHONE
07/18/2013 NOTICE OF VIOLATION ISSUED
03/25/2014 VIOLATION CLOSED