Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T13DV05172
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/28/2013 | INSP - INITIAL CODE ENFORCMENT | Approved | No handrail on steps; 2 doors lacking steps; elec circuits coming out of exterior light fixture to front porch has exposed spliced conducters and was added without permit; water service connector is not approved type or material (rubber hose); evap cooler stand is not structurally sound; cooler is connected to electrical system via wiring that was not installed to code, including use of extension cord, and has splices with exposed conductors; lifeline to main electrical panel is missing sheathing at end, requires replacement; gas service line has not shut-off valve; window boarded on door; sewer line lacking cleanout and is not sealed properly. |