Case: T13DV04786
Case Details
Entered Date:
07/09/2013
Applicant:
FOUNDATION FOR HEALTH, RESEARCH & PREVENTION ATTN: HEIDEMANN GLENN A
Description:
Electric service violations
Case Violations
Case Number: T13DV04786
Case Status: REFERRED
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
Violation Date | Code Statue |
---|---|
07/09/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T13DV04786
Case Status: REFERRED
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected |
Completed Inspections
Case Status: REFERRED
Case Number: T13DV04786
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/01/2013 | INSP - INITIAL CODE ENFORCMENT | RHOLLAND | Approved | Service disconnect has sever deterioration at grounded/neutral terminal. This is due to loose connections causing heat damage to the conductor and insulation. There is also corrosion to the point of causing metal failure to the terminal. The spice connector has not been installed to manufactures instructions. ther are too many conductors in the connector. The srevice disconnects are located over the gas piping and meters. It is noted that there is additional electrical added on the exterior of the unit. |