Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

04/17/2013

Applicant:

WILLWAY 2 LLC

Description:

BACK UP PLUMBING

Case Violations

Case Number: T13DV02470
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 14
Violation Date Code Statue
04/22/2013 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
04/22/2013 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
04/22/2013 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
04/22/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
04/22/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (2) All dwellings or dwelling units shall have a kitchen, which shall include an indoor cooking area. The cooking area must be provided with a sink separate and apart from any bathroom sink or lavatory. Each kitchen sink shall have hot and cold running water necessary for its normal operation and use.
04/22/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
04/22/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation.
04/22/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (5) When a structure is equipped with a gas supply system, it must be installed and maintained in a safe, hazard-free condition.
04/22/2013 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
04/22/2013 T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons.
04/22/2013 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
04/22/2013 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
04/22/2013 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.
04/22/2013 T.C. Ch. 16, Sec. 16-12(f) ADDRESS DISPLAY. (1) General requirements: a. All structures, whether new or existing, designed for human occupancy or use which have an assigned address shall display the address in a manner to be plainly legible and visible from the street or road fronting the property. e. The complete address shall be displayed on all corner buildings at a street intersection, for each side of the building facing any street. f. Addresses shall be displayed and visible from both directions of approaching vehicular travel. g. Numbers and letters shall be made of durable and clearly visible material. Paint shall not be considered durable for building addresses. h. Numbers and letters shall be of colors contrasting with the background of the sign or wall to which they are attached. i. Numbers and letters shall have a minimum proportion ratio of height to width of six to one (6:1). The formula is w = h/6, where w is width and h is height in inches. j. Numbers shall not be spelled. k. All height requirements stated in this section are minimum sizes.

Outstanding Inspections

Case Number: T13DV02470
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 9
End Date Description Inspector Results Comments
05/09/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX RVIDAL Item closed
05/09/2013 NPO(PL)-PLUMBING SYSTEM & FX RVIDAL Item closed
05/09/2013 NPO(PL)-GAS SUPPLY/CONNECT RVIDAL Item closed
05/09/2013 NPO(PL)-SEWAGE DISPOSAL (SYS) RVIDAL Item closed
05/09/2013 NPO(HC)-COOLING RVIDAL Item closed
05/09/2013 NPO(HC)-HEATING & VENTILATION RVIDAL Item closed
05/09/2013 NPO - SMOKE ALARMS RVIDAL Item closed
05/09/2013 NPO - EXT. BUILDING MAINTENANC RVIDAL Item closed
05/09/2013 NPO - INT. BUILDING MAINTENANC RVIDAL Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV02470
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/17/2013 INSP - INITIAL CODE ENFORCMENT RVIDAL Approved Found where the trailer is not connected to the main sewer due to the main line is backed up. The tailer is backed up inside at the bathtub and is currently full of sewage. The water is leaking at the connection to the trailer with a hose due to the connector not sealed properly at the connector. The tenants have been getting the water from the tub with a bucket and dumping at another trailer to get rid of the water and the sewage. The electrical line to the trailer OK but has globes missing on the light fixturs, expose wiring through out the interior of the trailer with some of the outlets not working. The heater and the cooling systems not working. Has no gas to the property and the water heater not working leaving no hot water to the trailer. Has no smoke detectors or the steps on the trailer are not working or not out. The trailer will be condemn due to the raw sawage on the ground, water leaking on the exterior, plumbing backing up on the interior and no cooling or heating. Will do N.O.V. RV.
05/09/2013 INSP - FOLLOW UP CODE ENFORCE RVIDAL Approved The trailer has been removed from the property and the space is a vacant lot. The trash and debris is still on the property and will be cleaned up. Colleen Bigman assisted on the inspection. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T13DV02470
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
04/22/2013 CONTACTED BY PHONE
04/17/2013 RED CROSS / PRIMAVERA
06/06/2013 MENTOR ASSISTANCE
06/06/2013 NOTICE OF VIOLATION ISSUED
06/06/2013 VIOLATION CLOSED