Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE
Address:

Entered Date:

02/11/2013

Applicant:

FOREST I. & BEULA L. SEAMAN REVOC TR

Description:

COMMUNICATION CALLED THAT THE TRAILER HAS AN ELECTRICAL FIRE ALPHA TRUCK ON SITE

Case Violations

Case Number: T13DV00838
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Violations: 9
Violation Date Code Statue
02/12/2013 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
02/12/2013 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
02/12/2013 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
02/12/2013 T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration.
02/12/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
02/12/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
02/12/2013 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
02/12/2013 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
02/12/2013 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.

Outstanding Inspections

Case Number: T13DV00838
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
05/01/2013 NPO(EL)-MAIN/PANEL/SUB/DISCONT AVINDIOL Item closed
05/01/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX AVINDIOL Item closed
05/01/2013 NPO(PL)-PLUMBING SYSTEM & FX AVINDIOL Item closed
05/01/2013 NPO - EGRESS AVINDIOL Item closed
05/01/2013 NPO - SMOKE ALARMS AVINDIOL Item closed
05/01/2013 NPO - EXT. BUILDING MAINTENANC AVINDIOL Item closed
05/01/2013 NPO - INT. BUILDING MAINTENANC AVINDIOL Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV00838
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/09/2013 INSP - INITIAL CODE ENFORCMENT RVIDAL Approved Communication called that the Alpha Truck from T.F.D. was on site with a medical and the power was off. They found an electrical panel with arching inside the panel. I responded to the site and the main electrical panel for part of the lot spaces had the breaker for the space #18 had burned and melted the buse bar inside the electrical panel. The owner was on site and had moved the breaker to another location and was working and the trailer had power back on. The trailer on space #18 was the only one that lost power. The people in the trailer are buying the trailer from the property owner. Did go into the house and the trailer has issues and was lacking a smoke detector and had one installed while on site. Has electrical outlets and switches that are sticking out of the wall and exposing the wiring and the connection to the outlets and switches. Has light fixtures that are hanging from the ceiling by the wiring. The trailer has no heat and has a propane tank for the stove and the tank is under the kitchen cabinets inside the trailer. The water heater is for the trailer is sticking out of the trailer but has an electric in the kitchen cabinet inside the trailer. Will meet with the area inspector to go over the case. RV.
05/01/2013 INSP - FOLLOW UP CODE ENFORCE AVINDIOL Approved 05/01/13 FOLLOW UP INSPECTION TO FIND TRAILER VACANT // TENANT IN A NEW UNIT // PERMIT FOR ELECTRICAL PANEL UNDER # T13CM01763 WAS FINALED ON 04/12/13 // WILL MOVE TO CLOSE OUT THIS CASE // AV

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T13DV00838
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
03/20/2013 CONTACTED BY PHONE
05/01/2013 VIOLATION CLOSED
02/11/2013 CALLBACK

Documents

File Name Document Type  
None IMAGES VIEW
04-02-13 FOLLOW UP .JPG IMAGES VIEW
NEW PANEL UNDER PERMIT .JPG IMAGES VIEW