Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING
Address:

Entered Date:

01/10/2013

Applicant:

KIM SUK HOO & MYUNG SOO CP/S

Description:

FIRE/SMOKE AND WATER DAMAGE

Case Violations

Case Number: T13DV00219
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Violations: 6
Violation Date Code Statue
01/11/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
01/11/2013 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability.
01/11/2013 T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration.
01/11/2013 T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition.
01/11/2013 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
01/14/2013 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T13DV00219
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
06/10/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT GOODMAN Item closed
06/10/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX GOODMAN Item closed
06/10/2015 NPO - EXT. BUILDING MAINTENANC GOODMAN Item closed
06/10/2015 NPO - INT. BUILDING MAINTENANC GOODMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV00219
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/11/2013 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved INSPECTED THE STRUCTURE DUE TO FIRE AT 100 E CONGRESS. INSPECTION FOUND WATER DUMPING OUT OF ELECTRICAL FIXTURES AND MECHANICAL DUCT WORK . FLOORING WAS SATURATED. ROOF MUST HAVE DAMAGE DUE TO THE AMOUNT OF WATER ON THE ROOF AND ENTERING THE STRUCTURE. INTERIOR CEILING SHOWED SIGNS OF POSSILE WATER DAMAGE EVIDENCED BY AREAS OF PEELING PAINT AND PLASTER, AND CRACKING. ELECTRICAL WIRING WAS CUT AT THE WEATHER HEAD DUE TO BURNED WIRES AT THE WEATHERHEAD ENTRANCE. SERVICE PANEL WIRING SHOWED SIGNS OF FIRE DAMAGE.
06/10/2015 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved ALL REPAIRS MADE TO THE STRUCTURE AND COMPLETED UNDER PERMIT T13CMO06388 LETTER OF COMPLETION PROVIDED. COMPLIANCE/ CLOSE CASE.

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T13DV00219
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
01/14/2013 NOTICE OF VIOLATION ISSUED
06/12/2015 VIOLATION CLOSED
05/31/2013 CALLBACK