Description:

Holes in roof. Wiring not properly wired. The back gate is falling down.

Case Violations

Case Number: T13DV00157
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
01/28/2013 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
01/28/2013 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
01/28/2013 T.C. Ch. 16, Sec. 16-11(b) (3) VENTILATION. b. Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room.
01/28/2013 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
01/28/2013 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.

Outstanding Inspections

Case Number: T13DV00157
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
08/21/2013 NPO(EL)-WIRING/SWITCH/OUTLT/FX JHURD Item closed
08/21/2013 NPO - EXT. BUILDING MAINTENANC JHURD Item closed
08/21/2013 NPO - WORK WITHOUT PERMIT JHURD Item closed
08/21/2013 NPO - INT. BUILDING MAINTENANC JHURD Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T13DV00157
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/09/2013 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE: MET WITH OCCUPANTS. FRONT ENTRY, ENTRY DOOR. ROOM ENCLOSED, NO HEATING OR COOLING TO ROOM. MASTER BEDROOM CONVENIENCE OUTLETS SHOW OPEN GROUND UNDER TEST. BATHROOM GFCI DOES NOT OPERATE. SHOWS REVERSE POLARITY. BATHROOM HAS NOT VENTILATION. TOILET LOOSE AT BASE. KITCHEN LIGHTS UNDER CABINETS HANGING BY WIRING. DINING ROOM CONVENIENCE OUTLETS SHOW OPEN GROUND UNDER TEST. STEP DOWN INTO ADDITION. 100 AMP SERVICE: TREE BLOCKS 3' CLEARANCE FOR SERVICE. NOT LABELED. MIXED BREAKERS, DO NOT SIT IN PANEL PROPERLY. OPEN JUNCTION BOX ABOVE PANEL. OPEN UNSECURE ROMEX IN LAUNDRY ROOM. ADDITION USED AS LIVING ROOM. NO HEAT OR COOLING IN ROOM. BATH OFF LIVING ROOM SHOWS OPEN GROUND UNDER TEST. PATIO ROOF GOES TO ALLEY WALL. (SET BACKS) PATIO SUPPORT POST CUT TOO SHORT, PIECE WEDGED UNDER POST. N/O/V 30 DAYS.
08/21/2013 INSP - FOLLOW UP CODE ENFORCE JHURD Approved VISITED SITE: MET W/OWNER. PROPERTY COMPLIANT @ THIS TIME. CLOSE/CASE

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T13DV00157
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
05/30/2013 CONTACTED BY PHONE
08/26/2013 VIOLATION CLOSED
05/01/2013 REINSPECTION FEE - FIRST

Documents

File Name Document Type  
CORRESPONDENCE T13DV00157.PDF DOCUMENTS VIEW