Case: T13DV00099
Case Details
Entered Date:
01/07/2013
Applicant:
SRAA PARTNERSHIP LLC
Description:
1). Broken windows on multiple buildings 2). Hazardous electrical connections to many AC units. 3). General neglect of exterior of structures.
Case Violations
Case Number: T13DV00099
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 3
Violation Date | Code Statue |
---|---|
02/11/2013 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
02/11/2013 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
02/11/2013 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
Outstanding Inspections
Case Number: T13DV00099
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/21/2013 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JHURD | Item closed | |
03/21/2013 | NPO - EXT. BUILDING MAINTENANC | JHURD | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV00099
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/07/2013 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED SITE: MET WITH MANAGER/MAINT ON SITE. WENT OVER ISSUES. AC UNITS ON NORTH SIDE OF BUILDING CONNECT TO AC OUTLET ON EXTERIOR OF BUILDING, SOME AC UNITS HAVE BEEN REPLACED, SOME POWER SOURCE OUTLETS REPLACED. ONLY ONE HAS PROPER WEATHER PROOF BOX INSTALLED. OTHER POWER SOURCE OUTLETS ARE OPEN TO ALL EXTERIOR ELEMENTS. DEEMED HARZDOUS ALL SHOULD HAVE WEATHER PROTECTED BOXES. AC UNITS WITH GFCI PROTECTION LOCATED ON CORD WILL NOT HAVE TO HAVE GFCI PROTECTED CONVENIENCE OUTLETS INSTALLED. IF NO GFCI PROTECTION LOCATED ON CORD, GFCI CONVENIENCE SHALL BE INSTALLED. WINDOWS ARE WOOD FRAMED, WOOD FRAME DETERIORATING, FALLING APART, CAN PULL DETERIORATED WOOD FROM FRAME. N/O/V TO BE ISSUED. 30 DAYS. |
03/21/2013 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | VISITED SITE: WEATHERPROOF BOXES INSTALLED ON ALL EXTERIOR A/C CONVENIENCE OUTLETS. WINDOW FRAMES REPAIRED, DETERIORATED WOOD IN AREAS REPLACED. COMPLIANT CLOSE/CASE. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T13DV00099
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
02/13/2013 | CONTACTED BY MAILING |
02/13/2013 | NOTICE OF VIOLATION ISSUED |
06/06/2013 | VIOLATION CLOSED |