Case: T13DV00099

Parcel: 117072640


Addresses:

435 E 18TH ST


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T13DV00099

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
01/07/2013 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE:
MET WITH MANAGER/MAINT ON SITE.
WENT OVER ISSUES. AC UNITS ON NORTH SIDE OF BUILDING CONNECT TO AC OUTLET ON EXTERIOR OF BUILDING, SOME AC
UNITS HAVE BEEN REPLACED, SOME POWER SOURCE OUTLETS REPLACED. ONLY ONE HAS PROPER WEATHER PROOF BOX INSTALLED. OTHER POWER SOURCE OUTLETS ARE OPEN TO ALL EXTERIOR ELEMENTS. DEEMED HARZDOUS ALL SHOULD HAVE WEATHER PROTECTED BOXES. AC UNITS WITH GFCI PROTECTION LOCATED ON CORD WILL NOT HAVE TO HAVE GFCI PROTECTED CONVENIENCE OUTLETS INSTALLED. IF NO GFCI PROTECTION LOCATED ON CORD, GFCI CONVENIENCE SHALL BE INSTALLED.
WINDOWS ARE WOOD FRAMED, WOOD FRAME DETERIORATING, FALLING APART, CAN PULL DETERIORATED WOOD FROM FRAME.
N/O/V TO BE ISSUED.
30 DAYS.