Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T13DV00001
Case Details
Entered Date:
01/02/2013
Applicant:
TROLLEY APARTMENTS & BIG TROLLEY & TROLLEY VENTURES LLC
Description:
Parking Lot Lighting in violation of Tucson Pima Outdoor Lighting Code; height, cutoff, lumen and color temperature restrictions
Outstanding Inspections
Case Number: T13DV00001
Case Status: COMPLIAN
Case Description: LIGHTING VIOLATION
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/14/2013 | NPO - OTHER | LPUMPHRE | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T13DV00001
Case Description: LIGHTING VIOLATION
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/08/2013 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | Three double fixture light poles in middle of parking lot appear to have been changed to a drop type that despite globe, may be comply with full cutoff; lumens prior and after unknown. Fixtures are approximately 20' high; closest perpendicular residential lot line (to east) of the three poles is approx. 62'. Applicable under outdoor lighting code: 102.4.2 Additions or modifications less than 25 percent to existing uses or lighting shall require a submission of a complete inventory and site plan detailing all existing and any proposed new outdoor lighting. Photo in Sire. |
02/13/2013 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | Compliant; fixtures returned to a full cutoff. |
Outstanding Case Activity Conditions
Date | Name | Approved |
01/09/2013 | CITY OF TUCSON / PIMA COUNTY OUTDOOR LIGHTING CODE, Sec. 102.4.2: Additions or modifications less than 25 percent to existing uses or lighting shall require a submission of a complete inventory and site plan detailing all existing and any proposed new outdoor lighting. Any new lighting on the site shall meet the requirements of this code with regard to shielding and lamp type; the total amount of lighting after the modifications are complete shall not exceed that on the site before the modifications, or that permitted by this code, whichever is larger. | Not Approved |
Completed Activity Special Conditions
Case Description - LIGHTING VIOLATION
Case Number - T13DV00001
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date | Name |
01/14/2013 | CONTACTED BY PHONE |
01/09/2013 | CONTACTED BY EMAIL |
01/09/2013 | NOTICE OF VIOLATION ISSUED |
02/14/2013 | VIOLATION CLOSED |