Case: T12DV02779
Case Details
Entered Date:
04/10/2012
Applicant:
NORMAND COUVRETTE
Description:
RMIN: Electrical wirings in bedroom closet are exposed for central a/c heating. Electrical outlets do not work and exposed throughout, when washer being used next door the bathroom sink, toilet and shower overflow due to plumbing issue. Roof is rotted and gutters are falling down. All issues have been reported to Property Owner and no type of repair has occurred. NOTE: Occupant available for inspection Wednesdays after 2 pm or all day Friday.
Case Violations
Case Number: T12DV02779
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 8
| Violation Date | Code Statue |
|---|---|
| 04/19/2012 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 04/19/2012 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 04/19/2012 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
| 04/19/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 04/19/2012 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
| 04/19/2012 | T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
| 04/19/2012 | T.C. Ch. 16, Sec. 16-12(e) ACCESSORY STRUCTURES. All accessory structures, including but not limited to detached garages, fences and walls, must be structurally sound and free of disrepair. Examples of disrepair include missing slats, posts or blocks, or damage, deterioration or rot. Fences and walls cannot be constructed or covered with materials not designed or commonly used for that purpose, such as pallets and tarps. Fences and walls must be properly anchored so as not to be in danger of failure or collapse. |
| 04/19/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T12DV02779
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2012 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | DJOHNSTO | Item closed | |
| 12/19/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | DJOHNSTO | Item closed | |
| 12/19/2012 | NPO(PL)-PLUMBING SYSTEM & FX | DJOHNSTO | Item closed | |
| 12/19/2012 | NPO(PL)-GAS SUPPLY/CONNECT | DJOHNSTO | Item closed | |
| 12/19/2012 | NPO - INT. BUILDING MAINTENANC | DJOHNSTO | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV02779
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/18/2012 | INSP - INITIAL CODE ENFORCMENT | DJOHNSTO | Approved | No smoke detectors in the unit. Electrical outlet in living room is worn and connection is loose. Furnace/a/c unit is improperly installed in the closet of the bedroom and non permitted. Plumbimg backs up into shower during heavy use. Wood around/under all eaves/soffits of the unit is rotted, decayed, missing paint. Storage shed in rear has rotted, decayed wood. The roof of the shed is dilapidated. Send 30 day notice to property owner. Schedule follow up inspection. Photos in SIRE. |
| 09/12/2012 | INSP - FOLLOW UP CODE ENFORCE | DJOHNSTO | Approved | Storage shed in the rear has been removed. Washer & dryer now out in the open. Improper electrical receptacles used. Water heater installed improperly. No permit found. Improperly vented. Open cooling duct has cardboard closing it off. Furnace still installed in the bedroom closet improperly without permit. Breaker in closet trips when more than one appliance is used. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T12DV02779
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
| Date | Name |
| 07/18/2012 | CONTACTED BY PHONE |
| 04/20/2012 | CONTACTED BY MAILING |
| 06/06/2012 | CERTIFIED RECEIPT CARD |
| 04/20/2012 | NOTICE OF VIOLATION ISSUED |
| 12/19/2012 | VIOLATION CLOSED |
| 10/19/2012 | RESEARCH |
| 05/29/2012 | REINSPECTION FEE - FIRST |